Model
Pipe
Size
Nm
A391 (Grade)
DN 80
2160
A483 (Grade)
DN 100
3100
A484 (Grade)
DN 100
4250
A686 (Grade)
DN 150
6500
A688 (Grade)
DN 150
8720
A8810 (Grade)
DN 200
11000
A10816 (Grade) DN 250
17000
A12824 (Grade) DN 300
25500
Maximum operating temperature: 120°C (248°F)
Maximum working pressure: 16 barg (232 psig)
CORRECTION FACTOR
For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.
Operating pressure barg
0.3
psi
4
Correction factor
0.21 0.29
15
Flow rate
Dimensions mm
/h
scfm
A
B
3
1270
450
300
1824
520
300
2500
520
300
3824
680
400
5130
780
400
6470
780
440
10000
900
530
15000
900
600
0.6
1
2
3
9
14.5
29
44
0.38
0.53
0.65
Models A391 (grade) to A12824 (grade)
Weight
C
D
Kg
lb
940
700
58
128
960
700
74
163
960
700
74
163
1000
700
165
364
1030
700
208
459
1060
700
260
573
1100
700
450
992
1100
700
1200
2646
4
5
6
7
8
58
72
87
100
115
0.76
0.84 0.92
1
1.07
A
B
C
D
The ultimate filtration & drying technology
Technical data
TECHNISCHE DATEN
CARACTERISTQUES TECHNIQUES
DATI TECNI
Dimensions inch
A
B
C
D
17
12
37
28
3
4
20
12
38
28
1
2
20
12
38
28
1
2
26
16
39
28
3
1
4
2
30
16
40
28
3
1
4
2
30
18
41
28
3
3
4
4
35
21
43
28
1
1
2
2
35
24
43
28
1
1
2
2
9
10
11
12
13
130
145
160
174
189
1.13 1.19
1.25
1.31
1.36
Note:
1.
National legislation requirements with respect to
installation, maintenance and re-inspection must be
complied to.
2.
No alterations shall be made to the vessel without
written authority of the manufacturer and under no
circumstances can additional welding operations be
carried out on pressurised vessels.
3.
Can only be used as a pressure vessel and operated
within the specified limits as detailed.
4.
Should be installed away from harmful elements that
cause corrosion.
5.
Shall not be fixed to the floor without interposing
anti-vibration pads, which conform to the appropriate
British Standard.
6.
Draining of condensate shall be performed daily when
the vessel is in use.
DATOS TECNICOS
TEKNISKE DATA
TECHNISCHE DATA
No. of
Element
Elements
Model
1
E139 (Grade)
3
E88 (Grade)
4
E88 (Grade)
6
E88 (Grade)
8
E88 (Grade)
10
E88 (Grade)
16
E88 (Grade)
24
E88 (Grade)
14
15
16
203
218
232
1.41 1.46 1.51