3 OPERATING
ZONE 1 and 2 relays can be programmed to open the lock; you can store up to a maximum of
1000 user cards (AND their codes) for ZONE 1 and up to a maximum of 10 user cards (OR 10
codes) for ZONE 2. Moreover, ZONE 1 can be programmed in 3 modes to open the lock: access
by card (card only), by card or code (you can use the card or the code) and by combined access
(card and code together). ZONE 2 can be programmed for the bell.
3.1 Access to the setting mode
• Default admin code is 1234.
• Enter the default admin code 2 times (1234 - 1234). But:
a) if the default admin code entered is 2 digits, please insert 12 - 12;
b) if the default admin code entered is 3 digits, please insert 123 - 123;
c) if the default admin code entered is 5 digits, please insert 12345 - 12345;
The rest may be deduced by analogy and the maximum is 6 digits long.
• After entering the setting mode, the yellow LED lights up.
Warning: users codes must be different from administrator code.
Warning: ZONE 1 codes must be different from ZONE 2 ones.
3.2 Setting the access mode
In setting mode:
• Press
followed by
and you will hear a long beep. This indicates that you can get access by card only.
• Press
followed by
stays fixed and you will hear a long beep. This indicates that you can get access by card and
by code.
• Press
followed by
stays fixed and you will hear a long beep. This indicates that you can get access by card and
by code (combined access).
• Press
to exit the setting mode.
3.3 Setting the length of passwords
In setting mode:
• Press
followed by
a "BI" as reminder, then digit X (X=2, 3, 4, 5, 6):
a) if 2 - Password/code length is 2 digits (from 00 to 99).
b) if 3 - Password/code length is 3 digits (from 000 to 999).
The rest may be deduced by analogy and the maximum is 6 digits long.
The "BI" sound, indicates that the chosen length value was correctly set.
If the sound is "BI BI BI", indicates that the chosen length value is the same in use and can't
be modified.
• Press
to exit the setting mode.
Warning: once you modified the length value, all stored cards and passwords will be cancelled.
, the mode yellow LED blinks, press the
, the mode yellow LED blinks, press the
, the mode yellow LED blinks, press the
, the yellow LED blinks, press the
2 times, the light stays fixed
followed by
, the light
followed by
, the light
followed by
and you will hear
11

Publicidad

Tabla de contenido
loading

Productos relacionados para Dea Digipro

Este manual también es adecuado para:

Digislim

Tabla de contenido