Technical Data - Parker 200 Manual De Uso

Ocultar thumbs Ver también para 200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Weight
Model
(lb)
(Kg)
200
172
78
Electrical
supply inlet
Model
200
230/1/60
Calibration values
200
,

8.3 Technical data

Refrigerant
R407c (Kg)
Ac
(oz)
(Kg)
(CO2)
45.8
1.3
2.31
Compressor
1 MC1(AC/Wc)
RLA
LRA
(A)
(A)
7.5
24
Hot gas valve
Fan pressure Switch
9-HGV
12-PV
ON: 261 PSIg
66.7 - 69.6 PSIg
OFF: 203 PSIg
4.6 - 4.8 barg
ON: 18 bar
OFF: 14 bar
MIN.- MAX
Ambient Temperature
Compressed
Amb
After
During transport
and stockage
ion
installat
32-122° F
41-122°F
41-149°F
0-50°C
5-50°C
Fan motor
3 EV1 (Ac)
RLA
(A)
(HP)
0.6
0.14
High pressure switch
15-HP1
406 PSIg
28 barg
200
Connections
air inlet
Temp.
Compressed
air inlet/air
Condensate
outlet
drain
In
1.1/2" BSP-F
(with adaptor)
1/2" NPT-F
5-65°C
1.1/2"NPT-F
Maximum pro-
Minimum circuit
tection
ampacity
device rating
HACR(Ac)
MCA(Ac)
HACR(Wc)
(A)
(A)
7.8
10
High temperature
thermostat
Working Pressure
16-ST
248°F
120°C
Sound
pressure
level
dB (A)]
55
Minimum section
validated cable
for
electrical
connections
Ø
14AWG
Air - Side Max
203 PSIg(*)
14 bar(*)
5

Publicidad

Tabla de contenido
loading