P.
Setting
Function
range
O
0 ... 3
Object tracking
.
t
0 ... F
Output on delay
.
T
0 ... F
Output off delay
.
12 List of the parameters for adjusting the relay functionality
Parameter mode must be started before setting the parameters. The relay to be parameterised is selected
according to the following table depending on the device address.
FEIG ELECTRONIC GmbH
A detected object can be tracked by the motion detector
even if it is moving very slowly. The sensitivity is specified
with this parameter.
0: off
1: low
2: medium
3: high
If this function is activated, minor movements such as,
e.g. leaves, rain or snow can cause continuous activation.
A relay activation delay time can be set for each of both
time
available channels.
0: 0 s
1: 0.2 s
....
F: 3.0 s
The respective value set is a multiple of 0.2 s.
The settings A to F correspond to the values 10 to 15.
A relay dropout delay time can be set for each of both
time
available channels.
0: 0 s
1: 0.2 s
....
F: 3.0 s
The respective value set is a multiple of 0.2 s.
The settings A to F correspond to the values 10 to 15.
Address
Relay 1
Relay 2
Page 37 of 97
Manual
Description / note
1 3 5 7 9 B D
1 3 5 7 9 B D
2 4 6 8 A C E
MWD BP_Handbuch_mehrsprachig_10.doc
MWD BP
Factory
setting
0
0
2