4. Design and function
For increased temperature range
■
Extended temperature range with heatsink. This may be combined with fixed ML 25
mm and with extended types.
*) 20 for high pressure sensor
Fitted with flange
■
Design with flange from DN25 and
from PN6 or ANSI, all forms of the
sealing face. Explosion-protected
instruments are usually seal-welded
to the sensor component (in this case,
the hexagon is omitted).
Insertion length EL =
ML-flange thickness
WIKA operating instructions models LSO.06, LSO.25
heatsink
seal weld
EL from
sealing face
flange
ML from
sealing face
sensor
alternative
seal weld
15