LIGHTING INSTRUCTION:
The heater can be regulated to three different heat intensities: 1 - LOW – 2 - MEDIUM – 3 - HIGH.
Ignition mode: Piezoelectric ignition
•
Open the clip of the gas regulator.
•
Press down and turn the Control Knob to the 1 - LOW position and keep it pressed for 10-15
seconds more. Release the button, if the pilot flame goes out, repeat the above operation.
Note: On first lighting a new heater, it may be necessary to hold the control knob down for a longer
time in order to allow gas to flow to the pilot.
Once the heater is light at the 1 - LOW setting, turning the control knob to 2 - MEDIUM or 3 - HIGH
position will light the second and third panel respectively.
To turn off the heater, return the control knob to the "START" position and close the clip of the gas
regulator. The heater can only be turned off by closing the gas regulator clip.
CAPACITY ΚW
POSITION 1 – LOW: 1,4 Kw
POSITION 2 - MEDIUM: 2,8 Kw
POSITION 3 – HIGH: 4,2 Kw
CHANGING THE CYLINDER
Turn off the cylinder gas regulator clip and allow the heater to cool fully before removing and
replacing the cylinder. Do not attempt to remove the regulator while the heater is still running.
CONSUMPTION Kg/hour
- 18 -
0,104
0,208
0,310