3.3.3
Disposing of packaging
Packaging materials such as carton, nylon and wood are all products considered nor-
mal urban waste. These materials can be disposed of as per normal procedures.
If the appliance is destined to countries where there are specific waste laws, dispose
of packaging conforming with the local laws in force.
3.3.4
Handling appliance model BH+25T
ATTENTION!
Lift the appliance using a fork-lift truck of a suitable capacity. Check that the load is
stable and positioned correctly on the forks, especially if moving in areas where there
is uneven, slippery or sloping ground conditions. When moving and transporting the
load make sure the forks are positioned as low as possible guaranteeing greater sta-
bility and visibility. Open the forks for greater load stability. As the appliance weighs 45
kg two workers are required if it is to be moved manually.
3.3.5
Handling appliance models BH+50F - BH+80F - BH+180F
As the following models BH+50F - BH+80F - BH+180F have wheels they can be
manually moved by pulling.
3.4
Connecting to electricity supply
ATTENTION!
Check the electricity supply corresponds to the value given on the appliance ID plate.
Electrical works can only be carried out by specialised and authorised staff with prior
authorisation by the person in charge of the appliance. Connect the appliance to a cir-
ciut provided with an efficient earth socket. If necessary use suitable extension leads
guaranteeing safety. The section (thickness) of the extension lead must be greater
than the appliance power supply cable. This avoids any hazardous overheating.
Avoid pulling or twisting the power cable as this can damage the internal wires.
3.4.1
Three-phase appliance 400 volt 50/60 Hz and three-phase appliance 230
volt 50/60 Hz
The mixer is provided with a 2.5 m power supply cable. This cable has a 4x1 mm sec-
tion (thickness) for model BH+25T and a 4x1,5 mm section (thickness) for models
BH+50F - BH+80F - BH+180F. Connect the power cable to a three-phase electricity
supply and connect a suitable thermo-magnetic differential switch. Always connect
the earth cable.
3.4.2
Single phase appliance 230 volt 50/60 Hz
These models are provided with a 1,5 m long power cable with a 3x1,5 mm section.
Connect the power cable to a 220 volt 50/60 Hz single phase electricity supply and
connect a suitable thermo-magnetic differential switch.
If the appliance is for a voltage other than the ones previously mentioned, contact the
manufacturer. The appliance will be supplied without a power plug.
If the power cable has to be lengthened use a cable with the same section as the one
provided by the manufacturer.
Please refer to paragraph 5.1. checking connection to electricity supply.
15