CHAPTER 6
STARTING UP
DANGER
Before starting up the device it is necessary to read the previous points, especially "Hydraulic System" and
"Electrical Installation".
Basic operational start-up consists of:
1. Start the device pressing
2. Introduce the nominal pump
current:
- Press
and hold for 3
seconds.
- We view on the intermittent
screen the nominal current with
the ON led.
- Via the keys and
nominal current indicated on the
pump plate. See Note 1.
- Press
to validate.
NOTE 1
it is very important to introduce exactly the nominal current on the pump specifications plate.
BASIC PROGRAMMING MENU
• Press
+
for 5 seconds.
• Use the keys
or
to modify
the values.
IT
TYPE
BAR
P
1
rc0
rc1
2
r.01
r. 99
3
4
Sb0
Sb1
ADVANCED PROGRAMMING MENU
• Press
+
+
for 5 seconds.
• Use the keys
or
to modify
the values.
3. Introduce operating pressure:
- Press
- We view start pressure
flashing and the
- START ON led.
- Via the keys
the start pressure from 0.5 to
7 bar.
- Press
adjust the
4. Introduce stop pressure:
- Press
- We view on the screen the stop
• Press
to the next one.
SYSTEM REACTION
It allows selection of the units in which
the pressure between bar and psi is displayed
Rapid cycles alarm:
- rc0: deactivated.
- rc1: alarm activated, when it is detected, a delay is produced in start-up to protect the
pump.
- rc2: alarm activated, the pump stops when it is detected.
If the rapid alarm cycles are activated in the previous point (rc1), we can select the
period of time between 3 consecutive start-ups, in seconds. We consider as rapid cycle
between 1" and 99".
Allows activation or deactivation of the display standby mode (Sb1) (Sb0) to save energy. Sb0
• Press
to the next parameter.
for 2 seconds.
and
adjust
to validate.
for 3 seconds.
to validate and to move
to validate and to move
USE AND MAINTENANCE MANUAL
pressure flashing and the STOP
ON led.
- Via the keys
and
the stopping pressure from 1
to 8 bar.
- Press
to validate.
5. I device remains configured and
ready for use.
• The sequence of parameters is
as follows:
DEFAULT
SETTING
bar
rc0
5 seconds
• The sequence of parameters is
as follows:
EN
adjust
15