Wiring Diagram - Ferroli ECONCEPT ST Instrucciones De Uso

Ocultar thumbs Ver también para ECONCEPT ST:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13

5.5 Wiring diagram

L
N
230V
32
50Hz
16
44
130
A
Attention: Before connecting the room thermostat or the remote timer
trol, remove the jumper on the terminal block.
16
Fan
32
Heating circulating pump
42
DHW temperature sensor
44
Gas valve
72
Room thermostat
82
Detection electrode
95
Diverter valve
130
Hot water tank circulating pump
138
External probe
139
Remote timer control
186
Return sensor
188
Ignition electrode
246
Pressure transducer
256
Modulating heating circulating pump signal
278
Double sensor (heating + safety)
341
Exchanger probe
A
ECO/COMFORT contact
OPEN = eco/comfort selection enabled from control panel or remote timer con
CLOSED = eco/comfort selection disabled; Comfort mode remains activated
44
EN
188
82
DBM05D
fig. 34 - Wiring diagram
cod. 3540S814 -
186
DSP05
/201
(Rev. 00)
ECONCEPT ST
A
138
256
16
278
341
GND
246
OUT
+5V
42
95
72
139

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido