Overall inspection for corrosion, cut insulation,
connections. Repair replace as necessary.
Check fuel lines for tightening, leaks, cracks, etc.
Check all electrical connections, wires and plugs
Clean the cylindrical housing and fan
Inspect fuel filter (clean or replace if necessary)
Inspect burner and air and pressure settings, adjust
if needed
Conduct a combustion analysis
Inspect and clean combustion chamber
Inspect and clean photocell
Inspect and clean burner nozzle and air passage
around burner head
Inspect, clean and adjust ignition electrodes
Inspect and clean the oil pump fuel filter
Inspect and clean air blower assembly (fan, motor)
Inspect the hanging equipment and anchoring
structure
Inspect and clean the exhaust piping system
Tab. 2
• have the safety devices checked at least once a
year by qualified maintenance personnel;
• after cleaning and repair operations, check that all
air heaters components (inside, outside) are in
good condition. The air heater may only be
restarted if all safety devices have been properly
installed and checked.

7.2 Cleaning

Periodic cleaning is essential for proper and safe
functioning of the air heater. Depending of the
accumulation of excess soot, dust and dirt the
cleaning operation should be performed after
seasonal use (every 12 months) or at the end of
each production batch (e.g. 6 weeks).
More frequent cleaning operations may be needed
in case:
• the air inlet is obstructed by dust, dirt and
feathers;
• poor quality fuel is used;
Task
14
|
Daily
before use
• the air heater is functioning with very frequent on
and off heating mode.
WARNING
operating. Do not use gasoline or other types of
fuels or flammable solvents to clean the air heater.
The prerequisites for proper cleaning operation of
the air heater are:
• air heater has been stopped (see Chapter 6.2)
and disconnected from electrical line and fuel line;
• air heater is sufficiently cool if previously was
functioning;
• fan/motor assembly is completely still;
• suspended equipment or ladders to reach the air
heater; the system must comply with laws in
force;
• clean cloth and/or soft brush;
• compressed air with maximum 50 PSI/3.5 bar.
© Munters AB, 2019
Minimum Interval
6 weeks after
each production
before or after
batch
every season
Do not clean the air heater while it is
Yearly