When the UV-C fluorescent lamp does not work, replace it as follows:
1. disconnect the device by pulling the plug from the power supply socket
2. disconnect the device from the water circulation, remove any remaining water
inside and wipe dry
3. turn the fitting grip (10) clockwise, according to the „OUT" arrow (fig.),
4. remove the fitting,
5. remove the fluorescent lamp from the fitting and press a new one in until locked,
NOTE: Do not touch the glass of the fluorescent lamp; remove possible marks
with a dry cloth
6. place the fitting (10) along with the mounted fluorescent lamp (8) in the housing
(otherwise the fluorescent lamp will not work).
Replacement of UV-C fluorescent lamp of the sterilizer in a FZKN filter:
1. disconnect the sterilizer and filter from power supply by pulling the plugs from the
sockets,
2. drain water from the filter (following the operating instructions of the FZKN filter),
3. remove the quartz cover (7) along with the fitting (10) and fluorescent lamp (8), by
turning it according to the „OUT" arrow (fig.),
4. wipe the quartz cover (7) dry and remove the fitting (10) along with the fluorescent
lamp (8) from it,
5. remove the fluorescent lamp from the fitting and press a new one in until locked
NOTE: Do not touch the glass of the fluorescent lamp; remove possible marks
with a dry cloth
6. assemble the device in reverse order.
It is forbidden to dispose of used electric and electrical equipment in a trash bin.
Segregating and proper utilization of this kind of waste leads to conserving the reso-
urces of natural environment The user is responsible for delivering the used product
to a specialized collection point where it will be accepted free of charge. You can
obtain information about such a facility at the local authorities at the product seller.
The manufacturer grants a 24 month guarantee beginning on the date of purchase.
The guarantee covers defects arising from manufacturer fault i.e. defective materials
or assembly errors. It does not cover damage due to user's fault caused by improper
handling of the device or using the device for purposes discordant its destination.
Attention: any modification or disassembly attempt exceeding normal usage and
maintenance cause the guarantee void. In case of noticing improper operation of the
device send it with filled out warranty card to the manufacturer or distributor address.
The conformity of the production date stamped on the product and written in the
guarantee card is a prerequisite for accepting the guarantee. The following warranty
conditions do not exclude, limit or suspend user's rights derived from discrepancy of
the merchandise with the agreement. The guarantee is limited to repair or replace-
ment of the unit only and does not cover consequential loss or damage to animate
or inanimate objects.
DISASSEMBLY AND DISPOSAL
GUARANTEE CONDITIONS.