Adjustment channels
4.1.21 Thermostat function (Arr = 3)
after-heating
AH O:
Thermostat-switch-on
tem perature
Adjustment range:
0.0 ... 95.0 °C
Factory setting: 40.0 °C
4.1.22 Pump speed control
nMN, n1MN, n2MN:
Pump speed control
Adjustment range:
30 ... 100
Factory setting: 30
Arr 10 (n2MN)
Werkseinstellung R2 = 100 %

4.1.23 Operating mode

HND1/HND2:
Operating mode
Adjustment range:
OFF, AUTO, ON
Factory setting: AUTO
4.1.24 Relay overrun for
high effi ciency pumps
PuM1, PuM2:
Relay overrun
Adjustment range: 1,2
Factory setting: 1
PuM2 available in Arr 2,
3, 6, 7, 8 and 10 only
use of surpluse energy
AH F:
Thermostat-switch-off tem-
pe rature
Adjustment range:
0.0 ... 95.0 °C
Factory setting: 45.0 °C
The thermostat function works independently
from the solar operation and can e.g. be used for
use of surplus energy or an after-heating.
• AH O < AH F
the thermostat function is used for after-
heating
• AH O > AH F
the thermostat function is used for use of
surplus energy
is shown on the display if the second relay
output is activated.
A relative minimum pump speed is specifi ed for
pumps connected at the outputs R1 and R2 via
adjustment channels nMN, n1MN and n2MN.
Attention:
When using consumers (e.g. valves) which
are not pump speed controlled, the value
must be adjusted to 100 % in order to
deactivate the pump speed control.
For control- and service work the operating mode
of the controller can be manually adjusted by
selecting the adjustment value Manual Mode, for
which the following adjustments can be made:
• HND1 / HND2
Operating mode
OFF
: relay off,
display:
AUTO : relay in automatic operation
ON
: relay on,
display:
When the parameter is set to 1, the correspon-
ding relay will be switched on and off as usual.
In order to reduce the number of switching pro-
cesses for high effi ciency pumps, a relay over-
run can be effected by setting the parameter
to 2. The corresponding relay will then remain
switched on for an hour after the switch-off con-
ditions have been fulfi lled. The overrun will be
effected after a manual mode switch-off, too.
(fl ashing) +
(fl ashing) +
23