Safeline MX3+ Guia De Inicio Rapido página 27

Sistema telefónico para ascensor
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Other codes
Emergency signal in speaker
Additional input function
Additional input type
Indicator mode
Unit number
Alarm button delay time
Alarm button type
Change password
Code Data
Comments
*71*
- #
The speaker siren will sound at emergency call.
0 = Off (default)
1 = On
*73*
- #
Selects input function:
0 = None (Default)
1 = Filter, blocks the alarm input when active.
2 = LMS (Lift Monitoring System), sends a lift
monitoring alarm at input activation.
3 = Clear/Maintenance
4 = Call Delay
*74*
- #
0 = Normally-open contact, N/O (Default)
1 = Normally-closed contact, N/C
*78*
- #
0 = Standard (default)
1 = Strictly EN81-28
2 = Strictly single EN81-28
*82*
- #
Unit number [0] is set by default, and means that
the unit will respond immediately.
Unit number [1-9] is used when the units are
sharing the same phone line. When the unit
number is assigned, the specified unit is accessible
for configuration.
*87*
- - #
Delay time from pressing the alarm button until
activating the alarm.
00-25 seconds. Default = 05
*89*
- #
0 = Normally-open contact, N/O (Default)
1 = Normally-closed contact, N/C
*91*
- - - - #
Change password (default=0000).
27
English

Publicidad

Tabla de contenido
loading

Productos relacionados para Safeline MX3+

Tabla de contenido