3.3 ControlSystem installation
Fit the ControlSystem to the multiport filter valve
control. (See figure 1)
Select a location as near as possible to the turn-
ing centre.
Clean the surface with alcohol.
Lift the protective stickers and plug the
ControlSystem into the chosen place.
Watch the "ControlSystem" position. Screw
area should be closer to the rotation axis.
Secure the assembly by tightening the tape un-
der the control. Check that it is fixed properly.
4. START-UP
4.1 Starting up the equipment.
Follow the installation manual instructions for the
pump to start it up properly.
4.2. Initial configuration
The first time you start it up you need to link
Silenplus with ControlSystem (See figure 2)
WARNING: It is very important to follow the
order of the operations described here:
4.2.1 Starting up the Evopool
Connect the Silenplus pump to the power sup-
ply.
The system will start up and a set of lights indicates
that it has been activated.
If a ControlSystem has not already been linked to
it, the pump will not start up.
Silenplus is on standby waiting for the link to be
established. The 3 leds flash together.
4.2.2 Activating the ControlSystem
To prevent the battery running out before the
equipment is started up, the ControlSystem has an
internal ON/OFF switch that must be activated (See
figure 2)
CAUTION: Do not approach magnetic ele-
ments
to
ControlSystem
operation.
Ensure that no magnetic fields can affect the
proper operation of the system.
WITH
THE
PUMP
ELECTRICAL CURRENT (see 4.2.1):
Make sure the valve is in the intermediate posi-
tion between 1 and 4
Lift the cover, loosening the screw.
Activate the ControlSystem by moving the mini-
switch to the "ON" position.
When the battery is connected, ControlSystem
transmits a unique code for an interference-free link.
Flashing leds indicate that proper communication
has been achieved. The green LED will light.
Replace the cover and fix it with the screw.
Torque: 0.2 Nm.
during
this
CONNECTED
TO
THE
4.2.3 Calibrating the ControlSystem
The 6 valve positions must be indicated to the sys-
tem. For this purpose, use the following calibration
process (See Figure 3):
1 - Move the valve control to position 4.
Wait for the green LED is illuminated.
2 - Move the valve control to position 6.
Wait for the green LED is illuminated.
3 - Move the valve control to position 2.
Wait for the green LED is illuminated.
4 - Move the valve control to position 5.
Wait for the green LED is illuminated.
5 - Move the valve control to position 3.
Wait for the green LED is illuminated.
6 - Move the valve control to position 1.
The pump will start up in Remote Filtration Plus
mode. The corresponding LED will come on.
4.3 Multiple system
In an installation with several pieces of equipment,
Silenplus
must
ControlSystem activated in order.
Each piece of equipment is linked using a unique
code to prevent interference between them.
A Silenplus pump in standby mode will be linked to
the first ControlSystem activated.
WARNING: activate the ControlSystem of
the valve for the pump on standby.
4.4 In the absence of ControlSystem
If you do not have ControlSystem or prefer not to
use it, the system can work just as well manually.
Ignore the activation and calibration operations,
switch to Manual mode and then connect the
Silenplus.
4.5 Changing the ControlSystem
If it is necessary to replace the ControlSystem in a
system that is already linked, you will need to de-
lete the old serial number before linking the new
one.
To do this, with the Silenplus pump connected to
the power supply, keep the F button pressed down
for 10 seconds. Flashing leds indicate that the op-
eration has been carried out correctly.
The previous serial number will be deleted and the
system will go into "link standby" mode. Proceed as
indicated in 4.2.2.