Descargar Imprimir esta página

Nemaxx WL 10 Instrucciones De Uso página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Version: 10.0
20.09.2016
Programming
Please PROGRAM the wireless radio smoke detector to a system after the test operation.
1. Place all the smoke detectors in front of you and carry out the following instructions
without interruption.
2. First determine the main smoke detector (master).
To do this press the learning key 2x, the Learn LED is now green.
3. Determine the assistant detectors.
To do this press the learning keys 1x, the Learn LED is now red.
4. You can start the programming process once all assistant smoke alarms learning LED's
are red and only the main smoke alarms' LED is green.
5. Hold down the Test button on the main smoke alarm button for a few seconds (this now
sends a signal to the assistant smoke detectors), until the assistant smoke detectors
sound an alarm.
6. To complete the linking, the signal previously transmitted to the assistant detectors
must be returned do the master detector. You must push the test button on each
assistant smoke detector one after the other until the master smoke alarm confirms this
by an alarm sound.
7. When you have finished the whole process, all smoke detectors should be interlinked.
You can test this by pressing and holding the test button on the master smoke detector
for a few seconds. All smoke detectors should set of an alarm.
Maintenance and Cleaning
1. In addition to weekly testing, the alarm requires periodic cleaning to remove dust, dirt,
and debris.
2. Clean the alarm at least once a month to remove dust, dirt, or debris.
3. Use a vacuum cleaner with the soft brush, vacuum all sides and covers of smoke alarm.
4. If necessary, remove the battery and use a damp cloth to clean the alarm's cover.
Low voltage alarm
When the battery reached a low energy level, the detector will sound in about every 60
seconds to indicate that the battery must be replaced. When 9V goes low power, make
„di" beep every 45 s, when 1.5V goes low power, make „didi" or „dididi" every 60 seconds.
Notice
1. Test the smoke alarm weekly.
2. If the product does not work properly, please check the battery firstly.
3. If the battery is ok, please do not open the product by yourself, please contact the
professional.
4. Do not use the product in the humid, dusty and smoky environment.
Attention
Any man-made damage or improper operation of the product are not offered quality
guarantee by our company.
EN
3
Doc. No. : WL10-0001
Revision No.: 1.0

Publicidad

loading