Troubleshooting - Clarke BOS-18 Manual Del Operador

Ocultar thumbs Ver también para BOS-18:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

Problem
Motor will not start.
Motor fails to start / runs
sluggish.
Fuse / Circuit Breaker repeatedly
trips.
Clarke
®
Operator's Manual (EN) - BOS-18
Cause
No power.
GFCI tripped.
Interlock not depressed.
Defective switch/ Bad connection
Low voltage from excessive length
or undersized extension cord.
Defective start capacitor.
Defective start switch.
Defective start/run capacitor
Defective motor low voltage
Low voltage.
Bad connection.
Defective motor.
ENGLISH
EN
Action
Check power supply and connection
Reset GFCI.
Depress Interlock before activating
control lever.
Contact an authorized Clarke
Dealer.
Use a 14 Ga extension cord, not to
exceed 50' length.
Contact an authorized Clarke
Dealer.
Contact an authorized Clarke
Dealer.
Contact an authorized Clarke
Dealer.
Contact an authorized Clarke
Dealer.
Eliminate extension cord.
Locate power source closer to
work site. Have voltage checked by
a qualifed electrician.
Contact an authorized Clarke
Dealer.
Contact an authorized Clarke
Dealer.
- 7 -

Publicidad

Tabla de contenido
loading

Tabla de contenido