M INTEN NCE - SUB-COMPONENT NUMBERS
MAINTENANCE:
The mask's components, in particular the exhalation valve membrane and the valve
seat, must be checked before use. A correctly functioning exhalation valve and
membrane are just as important for the correct functioning of the mask as is the
replacement of the filters at the correct time.
Check/Replacement of the exhalation valve membrane:
Open the cover to the exhalation valve. Holding the edge of the membrane, pull it
carefully out. The valve seat must be clean and undamaged. If the membrane is
deformed, split, or otherwise damaged, it must be replaced with a new original
RSG-membrane (refer to maintenance intervals in table 3, page 8).
SUB-COMPONENT:
Sub-components which have a particular significance for safety are marked so that
they can be identified - refer to table 4, page 8.
APPROVED INSTITUTION
System approval by: DEKRA EXAM GmbH, Adlerstrasse 29, D-45307 Essen,
Germany, identification number 0158, has been involved in the construction phase
of RSG HALF MASK
Production control according to Module C2 of PPE regulation (EU) 2016/425: DEKRA EXAM
GmbH Zertifizierungsslelle, Dinnendahlstrasse 9 • 44809 Bochum: Germany (CE 0158)
-
Download Declaration of Conformity @ www.rsgsafety.com/en/declaration-of-conformity
TABLE 1.
CONSTRUCTION PARTS (Fig. 1):
Pos
Description
1
Head straps
2
Strap buckle fram
3
Buckle (quick release)
4
Buckle frame (quick release)
(GB)
Pos Description
5
Front piece
6
Neck strap
7
Inhalation valve membrane
8
Mask body
Pos
Description
9
Exhalation valve
10
Exhalation valve membrane
11
Cover (Exhalation valve)