Unit conversion

This digital kitchen scale allows you to weigh using the metric system (g, ml) or in the Anglo-American system
(lb:oz, fl'oz). Use the UNIT button (weight, volume of milk, volume of water) to get the desired unit - see figure 2.
Weight
Long press the UNIT button to select the weighing system - metric (g, ml) or Anglo-American (lb: oz, fl'oz).
Display of liquid volume (milk, water)
1.
Place the container on the weighing platform.
2.
Touch the button
to select the water/milk volume measuring mode. Place the liquid container on the scale. Press the button
and reset; LCD display "0".
3.
Pour the liquid into the container, the display shows the volume of the liquid (water/milk).
To display the weight of the liquid press the button UNIT and select the weight measuring mode. The LCD
4.
display shows the weight of the liquid.
Weight addition and tare function
These functions are used for measuring the weight of batches, gradually added to the previous amounts that
remain on the scale. Place the first batch on the scale and its weight will be shown on the display. Before
placing another batch on the scale, touch the button
can be performed repeatedly.
Each time you press the button
status, please wait a few moments. During the "0g" display, the "O" or "T" (depending on weight) icon in the
upper left corner of the display lights up to indicate that the additional batch or tare function is active. In case
of additional batch the max. capacity does not change. In the case of tare, the maximum capacity is reduced by
the total weight of all batches on the scale.
If the total weight of all batches is less than 200 g, the additional weight function is automatically used.
If the total weight for all batches on the scale is higher than 200 g, the TARE function will be used automatically.
Press the button
another batch, press
Note: You can turn off the scale using either the button
Warning Alerts
1.
The batteries are empty, replace them.
2.
Scale overload – max. load 5 kg is stated on the scale. Please remove the weighed batch
from the scale to avoid damage.

MAINTENANCE AND CLEANING

1.
Use a damp towel to clean the scale and make sure no water gets inside the scale. DO NOT USE chemical
cleaning agents/agents with abrasive effect.
Do not immerse the device into water!
Water volume
to reset the weight of the container, the display shows "0". Use the UNIT button
and the LCD display shows " ----- " or "0g". " ----- " it means unstable
to display the total weight of all the batches on the scale. If you want to weigh
and again reset the LCD display to "0".
Fig. 2
to reset the value on the display ("0"). This action
or it turns itself off automatically in 2 minutes.