Please read this manual carefully before starting or using the machine. All
employees who work with and use this unit or who are responsible for its
maintenance must be familiar with its operation and safety devices. It is very
important to follow the general safety instructions, as well as all applicable
accident prevention regulations issued by professional organisations.
2. Starting the anticalcium cleaner unit
Use hoses to connect the unit input and output nozzles to the corresponding
input and output nozzles on the mould or heat exchanger to be cleaned.
(Fasten the connector hoses with clamps).
Make sure that the electrical connection is correct (these units are factory set
to 380V/50HZ, contact the Technical Department should any change be
necessary).
Remove the cap from the storage tank of the anticalcium cleaner and fill it up
to the level indicated in the enclosed drawing with a mixture of water and
descaling product.
(Concentration of the mixture of water and descaling acid: 10 or 25%)
Check that the pump rotates in the right direction by pressing the black start
button (the pump should always turn clockwise). If pump turns backwards,
invert the two phases of the power supply.
After connecting the unit to the power supply, verifying the direction of
rotation of the pump and filling the storage tank, the anticalcium cleaner unit is
ready for operation.