Important: The max. operating voltage must not exceed the stated
highest continuous voltage U
Important: If the installation does not provide any medium
protection such as by means of a splitter or earth wire, an SG-100
must always be installed for medium protection before an SG-200
that provides fine protection.
Technical Data
SG-100/SG-200 General
Dimensions (WxHxD)
Weight
Casing
Temperature (T
Relative humidity
Protection rating
Test standard
Customs tariff number
Signal cores: connection
cross-section (single-wire/
fine-stranded)
Earthing terminal
connection cross-section
RJ45 connection
Protective functions
Specification
Surge arrester class
Rated voltage (U
Highest continuous voltage
DC (U
)
C
Highest continuous voltage
AC (U
)
C
Rated current at 45 °C (I
C
)
U
)
N
) <= 200 mA
L
.
142 mm x 81 mm x 27 mm
106 g (SG-100), 111 g (SG-200)
Plastic (fire-proof), black
Operation: -5 to +40 ºC
Storage: -40 to +70 ºC
Operation: 5 % to 95 %, non-
condensing
IP20
EN 61643-21
85363010
0.2 to 0.75 mm
0.5 to 1.5 mm
Pin 4 and 5
SG-100
Type 2P1
70 V AC/
100 V DC
120 V
85 V
2
2
SG-200
20 V AC
---
28 V
<= 60 mA

Publicidad