Ce Source Four Instructions; Safety Warnings - ETC CE Source Four Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CE Source Four instructions

0.7m
t 180°c
CE Source Four

Safety warnings

The CE Source Four high performance ellipsoidal spotlight is intended for
professional use only. Read entire User Manual before using equipment.
Please note the following safety warnings before use:
Do not mount the CE Source Four on or near a flammable surface.
Use the luminaire in dry locations only, where humidity does not exceed 90
percent. Luminaire is not intended for outdoor use.
Mount and support the luminaire only by the primary suspension yoke holes.
Suspend the luminaire from a hook clamp or a stand mount, using a securely
tightened steel bolt (up to 12 mm Ø), washer and locking nut.
In addition to primary suspension, attach a safety cable (Model 400SC) or
chain to the secondary suspension point on the luminaire (see page 5).
Open all four shutters completely before turning the luminaire on.
Always hang the CE Source Four with the colour frame retaining clip in the
locked position.
Always replace the lamp if it becomes damaged or thermally deformed.
Keep the luminaire at least 0.7 meters away from anything it is shining on.
Lighted objects at this distance or greater will not exceed 90ºC temperature
from projected light.
Disconnect the unit from power before all cleaning and maintenance.
Maximum ambient temperature: T
Maximum exterior surface temperature: T
A multilanguage label sheet is included with this manual. Affix the label of
the appropriate language over the existing warning label on the extension
yoke. Do not cover ETC trademark or CE mark.
Wiring and power information
A plug of at least 2.5 amp (220/240V) rating should be attached to the
luminaire's mains lead. The wires in the mains lead are 1.5mm
coloured in accordance with the following code:
Green and Yellow:
Blue:
Brown:
Warning: This luminaire must be earthed.
Current rating:
Operating frequency:
=45 ° C
a
=200ºC
max
Earth
Neutral
Live
120V/5 amp maximum
240V/2.5 amp maximum
50/60Hz
2
each and
7

Publicidad

Tabla de contenido
loading

Productos relacionados para ETC CE Source Four Serie

Este manual también es adecuado para:

405410419426436450

Tabla de contenido