Descargar Imprimir esta página

Olymp LavaSit DINER Instrucciones De Montaje página 6

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Mounting instructions for electricians
13. Electrical connection:
Caution:
The wash unit with power supply cable must not be
connected to the power supply using an extension
cable.
Arrange the power supply cable so that the plug is
easily accessible and can be isolated from the wall
socket.
In case several wash units are to be installed in-line,
the power supply cable must not be connected via
further units.
The safety regulations of the hairdressing trade must
be observed. Installation and operation must be in
accordance with the norm DIN VDE 0100.
During assembly work the complete system
must be isolated from the power supply and
secured against unintended switch-on!
In the wash unit, use only the plug-in connectors
supplied with the appliance and specified in the
mounting instructions!
Cables must be so arranged that they are not in the
vicinity or moving parts! Damage or crushing must
thus be prevented!
The power supply cable from the unit must be
arranged so that it is not jammed between the unit
frame and the floor.
Variants for single units:
13.1
Direct wiring variant: (fig. 5)
Caution: This type of connection must only be
made by a qualified electrician!
Connect the mains cable from the floor to the
supplied system socket (fig. 3)
Insert the socket into the system connector
underneath the cover section and fasten the locking
clip (fig. 4).
13.2
Mains cable variant: (fig. 6)
Route the mains cable with plug to the outside
through the backside of column
In-line installation variants:
13.3
Primary in-line unit with direct connection
+ secondary in-line unit: (fig. 7)
> installation of primary in-line unit - see 13.1
> installation of secondary in-line unit:
Route the distrubutor cable of the Primary in-line
unit behind the base to the secondary in-line unit
und plug in there: To do so, detach the control
box (4) from the lower surface of the chair, insert
the system socket of the distribution cable into
the control box and reattach the control box to
the lower surface of the chair.
Diner MO B+R
GB
Mountinge instructions for electricans
and appliance fitters
13.4
Primary in-line unit with mains cable
+ secondary in-line unit: (fig. 8)
> Installation of primary in-line unit – see 13.2
> Installation of secondary in-line unit – see 13.3
14.
Assembly:
14.1
Loosely bind the 2 pressure hoses (hot + cold) and
drain hose together using cable ties.
14.2
Hang the backside cover (1) onto the base:
Hold the cover at the front edge from both sides, pull
apart and draw it from the rear side onto the base:
Front edge of cover must engage in perpendicular
profile.
unit with in-line installation:
Lead the distributor cable through the cutout in the
backside cover.
14.3
Put in the front cover (2) under the seat.
14.4
only with in-line installation:
Attach mounting strips (5) for installation tunnel
onto the backside cover over the cutout at both units
(fig. 2).
Lay the installation tunnel onto the mounting strips.
Caution:
The ends of the installation tunnel must be fitted with
edge protection!
Fix 2 self-adhesive cable clips (6) to the inner side of
the installation tunnel fig. 2
Fix distributor cable in the cable clips.

Publicidad

loading

Este manual también es adecuado para:

Lavasit diner