M-8S - MERIT SERIES PowER CondITIonER • EnGLISH
REAR PANEL FEATURES (continued)
Rear Panel DIP Switch
A rear panel three position DIP switch is used to set
the sequence mode (+12V ON, +12V OFF, GND ON,
Mom/ Maint) which defines how the M-8S will react
to the signal presented on its REM input. The table
below summarizes the behavior which is described
in further detail below. Note that DIP switch posi-
tion 2 overrides the setting of DIP switch 1, and DIP
switch 3 overrides switches 1 and 2.
DIP 1
DIP 2
1 2 3
GND ON
12V ON
OFF
OFF
OFF
ON
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
ON
DIP Switch position #1 (Factory default is OFF)
DIP Switch position 1 defines how the M-8S will
behave when +12VDC is applied to the REM pin
on the Remote interface. If this switch is in the ON
position, the M-8S will sequence ON when +12V
is applied to the REM input. If this switch is in the
OFF position (+12V OFF) the M-8S will sequence
OFF when +12V is applied to the REM input. DIP
switches 2 and 3 must be in the OFF position (Main-
tained mode).
DIP Switch position #2 (Factory default is OFF)
DIP Switch position 2 defines how the M-8S will
behave when GND is applied to the REM pin on the
Remote interface. If this switch is in the ON position,
the M-8S will sequence ON when GND is applied to
the REM input. If this switch is in the OFF position
the M-8S will follow the behavior defined by DIP
Switch #1. DIP switch 3 must be in the OFF position
(Maintained mode).
6
DELAY 3
Note: The front panel SEQUENCE ON/OFF switch acts as an override. The SEQUENCE switch must be
MODE
DIP 3
in the ON position for any of the sequenced outlets to be activated.
MOM/MNT
Sequences the M-8S ON when REM = Open Circuit
+12V OFF
OFF
Sequences the M-8S OFF when REM = 12VDC
Sequences the M-8S ON when REM = 12VDC
+12V ON
OFF
Sequences the M-8S OFF when REM = Open Circuit
OFF
GND ON
Sequences the M-8S ON when REM is connected to GND terminal
GND ON
OFF
Sequences the M-8S OFF when REM = Open Circuit
Momentary
ON
Momentary
ON
Sequences the M-8S from ON to OFF or OFF to ON each time +12V is applied to the REM input.
Momentary
ON
ON
Momentary
DLY
1 2 3
ADJ
12V STAT REM GND
REMOTE PORT
DIP Switch position #3 (Factory default is OFF)
DIP Switch position 3 defines the switching prefer-
ence for switches or devices connected to the REM
pin on the Remote Interface. If this switch is in the
ON position, the M-8S will operate in Momentary
mode. If this switch is in the OFF position the prod-
uct will operate in Maintained mode.
Maintained switches, for example toggle switches
or push-ON / push-OFF push button latching
switches maintain their contact position until the
switch is actuated a second time. Thus a switch that
is closed will remain closed until the switch position
is changed (such as the Furman RS-1).
12V ON
1
12V OFF
GND
2
ON
MOM
3
MNT
FACTORY DEFAULT SETTING