7. Plug power supply cord to a grounded wall outlet
(Figure 3).
Grounded
3 Hole Outlet
Ground Pin
(120V)
FIG. 3
FOR SAFETY: Do not operate machine unless
cord is properly grounded. Do not operate
machine with damaged cord or plug. Do not
operate machine with the use of an extension
cord.

MACHINE OPERATION

FOR SAFETY: Do not operate machine unless
operator manual is read and understood.
WARNING: Do Not Use Flammable Liquids Or
Operate Machine In Or Near Flammable Liquids,
Vapors Or Combustible Dusts.
This machine is not equipped with an explosion
proof motor. The electric motor will spark upon
start up and during operation which could cause a
flash fire or explosion if machine is used in an
area where flammable vapors/liquids or
combustible dusts are present.
1. Adjust handle to a comfortable operating height.
Lift handle release lever and lower handle to
adjust. Release lever to lock handle in position, six
settings (Figure 4).
FIG. 4
ServiceMaster Dust Control 2000 Burnisher (09–02)
HANDLE
RELEASE
LEVER
Home Find...
Go To..
ATTENTION: Use caution when starting out.
Machine will jolt when twist grips are turned.
2. Start machine by pressing safety lock button and
turning twist grips forward. Release thumb from
safety lock button once machine starts (Figure 5).
FOR SAFETY: When using machine, go slow on
inclines and slippery surfaces.
FIG. 5
3. Once you begin operating machine, view pad
pressure meter and adjust pad pressure
adjustment knob if necessary. Operate machine
with meter needle in the green zone ONLY. Turn
knob counterclockwise to increase pad pressure
and clockwise to decrease (Figure 6).
FIG. 6
ATTENTION: Keep machine moving to prevent
floor surface damage.
OPERATION
SAFETY LOCK
BUTTON
PAD PRESSURE
ADJUSTMENT
KNOB
PAD PRESSURE
METER