OPERATION
TROUBLE SHOOTING
PROBLEM
Machine does not operate.
Machine circuit breaker trips
continuously.
SPECIFICATIONS
MODEL NO.
WIDTH
HEIGHT
WEIGHT
DRIVE MOTOR
PAD/BRUSH SPEED
POWER CORD LENGTH
BRUSH PAD DIA.
DECIBEL RATING AT OPERATOR'S EAR,
INDOORS ON TILE FLOOR
Specifications are subject to change without notice.
14
CAUSE
Machine unplugged.
Machine circuit breaker tripped.
Building circuit breaker tripped.
Faulty power cord.
Faulty wiring.
Faulty twist grip switch.
Faulty rectifier.
Too much pad pressure.
Soiled Pad.
Improper pad for application.
Faulty circuit breaker.
Worn motor brushes.
16915/ 54100
610mm (24 in)
1270mm (50 in)
32Kg (70 lbs)
120V – 1.5 hp 12AMP 60Hz
2000 RPM
23m (75 ft)
510mm (20 in)
<70dB(A)
Home Find...
Go To..
SOLUTION
Plug machine in.
Reset breaker on machine.
Reset breaker and change to differ-
ent circuit.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Adjust pad pressure knob.
Replace Pad.
Change to proper pad.
Contact Service Center.
Contact Service Center.
ServiceMaster Dust Control 2000 Burnisher (09–02)