9
Backlighting
The backlighting is switched ON/OFF by pressing and holding button (6).

Auto Off function

In order to preserve the batteries, the measuring device switches off automatically if it is
left idle for 3 minutes.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents
and solvents. Remove the battery(ies) before storing for longer periods. Store the device in
a clean and dry place.
Danger – powerful magnetic fields
Powerful magnetic fields can adversely affect persons with active medical implants
(e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical
clocks, precision mechanics, hard disks).
With regard to the effect of powerful magnetic fields on persons, the applicable national
stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic
fields" (occupational health and safety - electromagnetic fields) in the Federal Republic
of Germany.
To avoid interference/disruption, always keep the implant or device a safe distance of at
least 30 cm away from the magnet.
Technical data
Electronic measuring precision
Display accuracy
Vial
Operating conditions
Storage conditions
Power supply
Dimensions (W x H x D) 25
Dimensions (W x H x D) 40
Dimensions (W x H x D) 60
Weight (incl. batteries) 25
Weight (incl. batteries) 40
Weight (incl. batteries) 60
Subject to technical change without notice. Rev18W21
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must
be collected separately for disposal according
to the European Directive on waste electrical
and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=diglevpl
± 0,1° at 0° ... 1°
± 0,1° at 89° ... 90°
± 0,2° at 1° ... 89°
1 decimal place
± 1 mm/m
0 ... 50°C, 80%rH, no condensation,
max. working altitude 2000 m above sea level
-20 ... 70°C, 80%rH, no condensation
2 x 1.5V (type AAA/LR03)
240 x 66 x 30 mm
400 x 66 x 30 mm
600 x 66 x 30 mm
315 g