4
Voltage measurement AC
To measure voltage, set the rotary
switch to the "
the corresponding measuring range
(60 V - 300 V).
Then connect the measuring contacts
to the object to be tested.
Reading the scale (C):
Measuring
Scale
range
60 V
0 - 60
120 V
0 - 12
300 V
0 - 300
5
Current measurement DC
To measure current, set the rotary
switch to the "
the corresponding measuring range
(30 mA / 600 mA).
Disconnect the circuit before connecting
the meter. Then connect the measuring
contacts to the object to be tested.
Reading the scale (B):
Measuring
Scale
range
30 mA
0 - 300
600 mA
0 - 60
Disconnect the circuit again before
disconnecting the meter.
!
No currents above 600 mA may be measured in the
mA range. Currents above this level trigger the automatic
fuse in the meter (F 630 mA / 300 V, Ø 5 mm x 20 mm).
16
EN
" position with
Result
x 1
x 10
x 1
" position with
Result
: 10
x 10
black
red
red
black