Surface Temperature Measurement; Thermal Bridge Mode - Berner 219048 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
is turned on. The LCD then shows the laser symbol. To turn the laser off again, press the
temperature measurement key and the "Down" key again until the laser symbol disappears.
When taking measurements in a dark environment you can turn on the background illumination
for the display using the buttons temperature measurement and "Up".

Surface temperature measurement

To measure the temperature of an object, Press the
temperature mode.
Point the instrument at the object and hold down the trigger. The laser pointers will activate
showing the area in which the infrared sensor can see.
The display will show the current surface temperature
measurement spot. After releasing the trigger the display will hold the current measurement.
Highly reflective or transparent surfaces can affect surface temperature
measurements. If necessary, cover area with matte tape and allow tape to
acclimate to the surface temperature before measuring.

Thermal Bridge Mode

Thermal bridge mode compares the surface temperature with the ambient temperature. If the
temperature difference is large enough, the LED above the display will change from green to
either yellow or red to indicate the possible presence of a thermal bridge.
To active thermal bridge mode, press the
Point the instrument at the object and hold down the trigger. The laser pointers will activate
showing the area in which the infrared sensor can see.
The display will show the current surface
Temperature
temperature
The LED above the display will indicate the possible presence of a thermal bridge.
Green: Low temperature difference. No thermal bridge detected.
Yellow: Medium temperature difference. Possible thermal bridge present. Check again at a
later time to verify.
Red: High temperature difference. Thermal bridge detected. The display will flash the
surface temperature icon.
Check the insulation if a thermal bridge is detected.
of the object within the measurement spot along with the ambient
. After releasing the trigger the display will hold the current measurement.
23
button to enter surface
of the object within the
button to enter thermal bridge mode.

Publicidad

Tabla de contenido
loading

Tabla de contenido