Operating Instructions
PRO1100
Manual Temperature
Controls
Description
• The manual Temperature Control is
designed to regulate pool and spa
water temperature.
• There are two indicator lights on the
control panel to display the current
status of the unit.
• The thermostat knob may be
adjusted to maintain the desired
water temperature.
Indicator Lights
• There are two indicator lights on the
front panel that display unit status. The
GREEN light indicates that power to the
unit is on. The RED light indicates that
the unit is in heating mode.
C
F H
Capacitor
Figure 4 - PRO1100 wiring diagram
www.aquaprosystems.com
• The RED light may become
illuminated prior to heater start up.
The RED light will become lit when
the thermostat knob is set at or
above the water temperature.
• The unit has a built in time delay.
Every time the unit turns off there is a
five-minute time delay until the unit
may be restarted. The HEAT light may
turn on during this delay cycle. Do not
rotate the thermostat knob during this
time delay. Rotating the knob during
this cycle may reset the time delay,
causing the unit to wait an additional
five minutes prior to startup.
Water Temperature Set Point
• Temperature set point range is 45°F
to 107°F. Rotating the thermostat
knob clockwise will increase the
temperature set point, while rotating
Fan
Motor
White
Yellow
Orange
Blue
Red
Black
Compressor
Phone: (877)-278-2797
Temp
Blue
Black
240V-24V
Transformer
C
R
S
Green
Light
Red
Llight
4
counterclockwise will decrease the
temperature set point.
• A floating thermometer may be
placed in the pool or spa to monitor
water temperature.
• To initially calibrate the thermostat to
the desired set point, turn the
thermostat knob fully clockwise. The
unit will turn on and begin heating
after a possible five minute time delay.
Allow the unit to run until pool or spa
water reaches the desired temperature.
Slowly turn thermostat knob counter-
clockwise until the unit turns off. The
unit will now maintain this water
temperature, providing the circulation
pump is running.
PRO1100
High
Pressure
Time
Delay
Black
Low
Pressure
Thermostat
Nuet Hot In Out
Gray
Water
Pressure
1
2
TB1
3
4
Gray