PRO1100e
TCE
and
PRO1300
TCE
Black
Water Sensor
Black
Black
Defrost Sensor
Black
To Remote System
(If Applicable)
High Pressure Switch
Closed = OK
Opened = High Pressure
Low Pressure Switch
Closed = OK
Opened = Low Pressure
Flow Switch
Closed = Flow
Opened = No Flow
Figure 7 - PRO1100e TCE & PRO1300 TCE wiring diagram
Time Clock Override
(TCO) Operation (cont.)
T2
T1
INSIDE
INSIDE
CONTACTOR
CONTACTOR
HEAT
HEAT
FOR THE
FOR THE
PUMP
PUMP
TIME
TIME CLOCK
CLOCK
OVERRIDE
OVERRIDE
L3
L4
BREAKER
BREAKER
TIME
TIME
CLOCK
CLOCK
Figure 8 - TCO wiring diagram
(optional)
MY-TECH PH-111A
SPR1
SPR2
REVR
HP
LP
FLO
WS
DS
AS
P/S
Black
Black
Blue
Blue
Orange
Orange
•
This unit is prepared at the factory with
the "FIL" mode set to the "off" position.
You will need to set the heat pump's
hours of run time in the "FIL" mode to
"2" hours. See "activating and setting
system run time" below to set the run
time. Leave your time clock set to the
desired pump and filter operation time.
This will enable the heat pump and filter
system to run the desired hours of the
day and also provide the benefit of
checking if heat is needed every 4 hours.
It will do this by running the pump and
filter system for 15 minutes. If heat is
needed, it will continue to run until the
pool has reached the set temperature. If
no heat is needed, the system will turn
FILTER
FILTER
off and continue checking for heat every
PUMP
PUMP
4 hours. This provides a couple of added
benefits. Pools will lose most of their
heat at night if left uncovered, however,
since the unit is checking for and adding
Phone: (877)-278-2797
PRO1300, PRO1100e, PRO1300h/c, PRO1100,
PRO1300h/c TCE, PRO1300 TCE, PRO1100e TCE
JANDY
AC
F1
F2
F3
12
~8
~12
Blue
Gray
12 VAC
Blue
L3
L4
COMPRESSOR
24 VAC
pool pump
contactor coil
Pool Pump
7
Brown
Brown & White
FAN
Red
Yellow
Blue
Black
24 VAC
Yellow
24
Compressor
Yellow
Vac
Contactor Coil
C
R
S
Black
heat when needed, it prevents long
recovery times when compared to non-
TCO units. The other benefit is that some
states and electric utility companies offer
a discount for off-peak usage of
electricity. Please contact your electricity
provider if you have questions.
Activating and Setting System Run
Time – TCO Operation
•
To set the run time of the system,
push the "SET" button repeatedly
until "FIL" displays. Then using the
"up" and "down" arrows, set the
hours to "2". The range of hours is
"off" to 2, 3, 4,... up to 23 hours to
"on". By selecting "2" the heat pump
will run every 4 hours for 20 minutes,
checking if heat is needed. The unit
leaves the factory with the "FIL"
mode set to "OFF".
www.aquaprosystems.com
L2
L1
Run Cap
H
F
C