Electrical Connection; Problems & Solutions - tomado TIH5501B Instrucciones De Uso

Placa de cocina de inducción
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
OUTER DIMENSIONS
In the drawing below,
all the dimensions are
displayed in mm.
Sufficient clearance around
the hob is essential for a safe
use of the hob. Check that
there is sufficient clearance.
The minimum distance
of the hob to a cooker hood
should be at least 650 mm.

ELECTRICAL CONNECTION

Attention: this hob includes a power cord with a plug. The connection is a 1 fase-connection.
• Check that the voltage in your home corresponds with the voltage printed on the bottom of the appliance.
• The earthing of the appliance is compulsory by law.
• Attention: the connection point must always be accessible.
If there is an error, an error code will be shown at the displays.
Error code
Cause
E1
Supply voltage is too high.
E2
Supply voltage is too low.
E3/E4
The cooking zone is overheated.
E5/E6
The hob is overheated.
F3/F4
F5/F6
Induction sensor is defect.
F7/F8
F9/FA
Coil temperature sensor is defect.
FC/FD
PROBLEMS & SOLUTIONS
Solution
Have the installation checked by a qualified electricien.
Have the installation checked by a qualified electricien.
Wait for the temperature of the cooking zone to drop and switch it on again.
Switch the appliance off and let the cooking zones cool down.
Contact the service department of Inventum.
Contact the service department of Inventum.
EN - 22

Publicidad

Tabla de contenido
loading

Tabla de contenido