4. INSTALLATION
Remove all packing materials from the fixture.
Check that all foam and plastic padding is re-
moved. Screw the equipment into a 19" rack, can
be mounted in any position; make sure adequate
ventilation is provided around the product.
Always disconnect from electric mains power
supply before cleaning or servicing.
5. SETUP AND OPERATION
Resetting The System Warning
This will reset the controller to its factory defaults.
This will erase all programs and settings.
1) Turn off the unit.
2) Press and hold BANK UPand AUTO/DEL.
3) Turn on power to the unit (while still holding
BANK UPand AUTO/DEL).
DMX
In
1st Product
P. 6
Tecshow Navigator 2 | English version
DMX
DMX
Out
In
2nd Product
DMX Cabling
DMX cabling is required to get DMX values from the
board to the products. Connect the DMX cable from
DMX Out of the board to DMX In of the first product
in the rig. Then connect another DMX cable from
DMX Out of the first product in the rig to DMX In of
the next product.
Continue connecting until all the products are con-
nected like below picture:
DMX
DMX
Out
In
3rd Product
DMX
Additional
Out
Products