USE AND MAINTENANCE MANUAL
CHAPTER 7

MAINTENANCE AND TROUBLESHOOTING

DANGER - ELECTRIC SHOCK RISK
Make sure the machine is disconnected from electric power supply, before performing mainte-
nance operation.
In ordinary conditions, PENTAIR FLOTEC AUTOJET series electropumps do not require any maintenance. To prevent
possible problems, it is advisable to periodically check the pressure supplied and current absorption. A reduction of
the pressure may indicate that the electropump is worn. Sand and other corrosive materials present in the delivery
fluid cause a rapid wear and a reduction of performance. In this case, it is advisable to use a filter. An increase in cur-
rent absorption indicates the presence of abnormal mechanical friction in the pump and/or the motor.
If the electropump is not going to be used for a long period of time (i.e. one year), it is advisable to empty it comple-
tely (by opening the drain cap, see Fig. 1 n. 10), rinse it with clean water and store it in a dry location, where it can be
protected from frost.
PROBLEM
1) THE PUMP IS NOT
RUNNING
2) THE PUMP DOES NOT STOP
3) THE ELECTROPUMP DOES NOT
PUMP WATER, THE MOTOR DOES
NOT RUN
4) THE MOTOR RUNS BUT THE
ELECTROPUMP DOES NOT PUMP
LIQUID
5) THE ELECTROPUMP STOPS
AFTER RUNNING FOR A SHORT
PERIOD OF TIME BECAUSE ONE
OF THE THERMAL MOTOR CIRCU-
IT BREAKER TRIPS
If the problem persists despite the recommended corrective actions, contact the Customer Assistance Service.
12
POSSIBLE CAUSE
1) No water.
2) Pump stalled.
3) No current.
4) PRESSUREMATE is faulty.
1) Reset button blocked.
2) The pump sucks air.
3) PRESSUREMATE faulty.
1) No power.
2) Motor protection tripped.
3) D efective condenser.
4) Shaft blocked.
1) The pump is sucking air.
1) The power supply does not
comply with the data on the
nameplate.
2) A solid object is blocking the
impellers..
REMEDY
1) Red LED light on (FAILURE). Identify the cause, and then restart
by pressing the RESTART button.
2) Identify the cause and unblock the pump.
3) Check that power is present and that the plug has been inserted
properly. The Green LED light (power On) is off.
4) Contact the Customer Assistance Service.
1) Inspect the pump and clean it if necessary.
2) See point 4.
3) Contact the Customer Assistance Service.
1) Check that power is present and that the plug has been inserted
properly. The Green LED light (power On) is off.
2) Identify the cause, and then restart by pressing the RESTART
button. Wait until the system has cooled down if the thermoregula-
tor has intervened.
3) Contact the Customer Assistance Service.
4) Identify what caused the block:
a) make sure that the power supply cable has been unplugged
b) remove the fan cover
c) Try to unblock the shaft by turning the cooling fan.
Contact customer services if the problem persits
1) Check to ensure that joints are leak proof.
- check that liquid levels have not decreased beneath the foot valve.
- Check to ensure that the foot valve is unblocked and leak proof.
1) Check the voltage on the power supply cable leads.
2) Contact customer services.