This fireplace is a zero clearance design. No combustibles can be placed on the top surface
of the fireplace. Combustibles may be installed to the edge of the unit. Insulation and vapor
barrier should be placed a minimum of 2 inches from the unit. Build the framing according
to the specifications shown in the below table & figure 3.
A
MODEL
36EB110-GRT
36EB220-GRT
8"
36EB111-GRC
36EB221-GRC
Section 3: Recommended Power Supply Wire
For 36EB110-GRT & 36EB111-GRC installations use three non-metallic
sheathed cables with ground wire for the power supply. Use the appropriate wires to
meet local and national electrical codes for rated power consumption.
For 36EB220-GRT & 36EB221-GRC installations use four non-metallic
sheathed cables with ground wire for the incoming power supply. Use the appropriate
wires to meet local and national electrical codes for rated power consumption.
Recommended Wire and Fusing Requirements
Use appropriate wire to meet local and national electrical codes for rated power
consumption. All wire gauges should be 12 gauge solid wires with a dedicated 15 amp
breaker for 120 volts. For 208/240 volts Builders Box models use two dedicated
15 amp breakers.
Allow at least 8 in of service cable for connecting power supply wire to junction box on
fireplace insert when installing before finishing wall. Allow up to 4 feet of service cable
for connecting power supply wire to junction box on fireplace insert after finishing wall.
The control box is supplied with a six meter long cable.
SECTION 2: FRAMING
Section 1: Framing
B
C
D
35"
23.8"
24"
Framing Specification: Figure 3
D
E
F
G
18"
36"
33.5"
H
E
G
F
Specifications
E-5
H
I
J
34.7"
23.6"
7.8"
I
J
K
L
M
51"
36"
36"
L
K
M