6. Measurment Operation
6-1. Hold the meter by its Handle Grip and point it toward the
surface to be measured.
6-2. Pull and hold the Trigger to turn the meter on and begin
testing. The display will light if the battery is good. Replace
the battery if the display does not light.
6-3. While measuring, the SCAN display icon will appear in the
upper left hand corner of the LCD.
6-4. While continuing to pull the Trigger:
•Push the "Laser/ Backlight" button once to turn on the laser pointe.
When the laser is on, the laser icon "
Push the "Laser/ Backlight" button two times to turn on the backlight.
Push the "Laser/ Backlight" button three times to turn the laser off.
Push the "Laser/ Backlight" button four times to turn both the laser and
backlight off.
•Select the temperature units (°C or °F) using the "°C/ °F" buttons.
•Select the Max/Min mode using the "Max/Min" buttons.
6-5. Release the Trigger and the HOLD display icon will appear on
the LCD indicating that the reading is being held.
6-6. The meter will automatically power o on approximately 8
seconds after the trigger is released.
Note: Measurement Considerations
Holding the meter by its handle, point the IR Sensor toward the object whose
temperature is to be measured. The meter automatically compensates for
temperature deviations from ambient temperature. Keep in mind that it will take up
to 30 minutes to adjust to wide ambient temperatures are to be measured followed
by high temperature measurements, some time (several minutes) is required after
the low (and before the high) temperature measurements are made.
This is a result of the cooling process which must take place forthe IR sensor.
" will appear on the LCD.
EN
5