Overview
5.
Configuration
6.
•
Before installing the mini pan/tilt dome, it must be configured though setting the
dipswitches that are located inside the dome. To reach the dipswitches, open the dome by
rotating the transparent cover (2) clockwise and lifting it.
•
Be very careful not to touch any other part inside the housing while setting the switches,
as damage might occur.
•
SW1~SW4 are used to set the ID of the device, allowing for a system with up to 15
unique devices. However, when using the IR remote control device, only the 9 first
(lowest) IDs can be controlled.
•
SW5 and SW6 set the BAUD rate, SW7 the used protocol and SW8 sets the type of alarm
contact to normally open (N.O.) or normally closed (N.C.).
ID
SW 1
0
OFF
1
ON
2
OFF
3
ON
4
OFF
5
ON
6
OFF
7
ON
8
OFF
9
ON
10
OFF
11
ON
12
OFF
13
ON
14
OFF
15
ON
•
Close the dome by placing the transparent cover (2) back and turning it counter
clockwise. Secure the transparent cover by mounting a small screw in the hole in the
housing.
00 (17/09/2008)
CAMCOLD7
SW 2
SW 3
SW 4
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
Dome
1. Camera
2. Transparent cover
3. Non-transparent housing
4. Mounting plate
5. Input/output cable
5a. video output (BNC)
5b. power input
5c. communication
IR receiver
6. DC power input
7. RS-485 D+
8. RS-485 D-
9. Ground
OFF
SW 5
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
4
SW 6
BAUD rate
ON
2400
ON
4800
OFF
9600
SW 7
Protocol
ON
Native
OFF
PELCO
SW 8
Alarm type
ON
N.O.
OFF
N.C.