HAEGER BH-120.002A Instrucciones De Uso página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The appliance must be connected to a power socket with a suitable
ground connection.
For extra protection we recommend installing a residual differential current
device (RDD) not exceeding 30mA in the electrical circuit supplying the
bathroom. Ask your installer for advice.
Installation
For a permanent electrical connection, we recommend you seek a
professional installer who can perform simple electrical installations in
compliance with the low-voltage regulations and applicable standards. An
incorrect installation could cause accidents and breakdowns. For its mains
connection, we recommend you use an electrical cable with 1 mm2 cross-
section. The installation must include an automatic power cut-off system.
Do not install the appliance in a ventilation area.
Always observe the minimum safety distances between the heater and any
walls or obstacles. Do not install the appliance behind a door.
Do not touch the quartz tub with your hands when connecting or installing
the appliance. Any resulting stains could reduce the life of the heating tube.
For fixture to the wall, proceed in the following manner:
1. Unscrew by one turn the side screw which determines the inclination of
the appliance.
2. Turn the wall support to the end of is travel.
3. Unscrew the screw which fasten the cover of the wall support and
remove the cover.
4. Determine the placement of the appliance and, mark the holes in the
wall where you are going to mount the radiator.
5. Drill the marked holes and insert the wall plugs provided.
6. Attach the brackets to the wall using the screws provided.
The wires in the main lead are coloured in accordance with the following
code:
yellow/green wire = earth wire
brown wire = live wire L
blue wire = neutral wire N
The green and yellow wire must be connected to the terminal marked
7.
with letter E or the earth symbol.
The blue wire must be connected to the terminal marked with the letter
8.
N or coloured black.
The brown wire must be connected to the terminal marked with letter L.
9.
Instructions for use