Unit Mounting
3.
GND NO COM NC
DT-RLC
REF 1418
GND NO COM NC
MODULO RELE WAY
WAY RELAY MODULE
POWER
IN-USE
POWER
IN-USE
DIN Rail Mounting
How to set the unlock delay time
4.
1). Power-on within 5 seconds, short-circuit S2 up to 3 seconds, the IN-USE indicator
fl ash.
2). Short-circuit S1 up to 3 seconds, and the IN-USE indicator always light.
3). Short-circuit again S2, at this time,the short-circuit time equal to unlock delay time.
(the IN-USE indicator flashes once per second, Less than two seconds by one
second calculation; The maximum setting time is 30 seconds.)
4). After S2 released, saved unlock delay, and exit the setting.
DIP Switch Setting
5.
The DIP switch in the back of the panel is used to set the address of the relay. Please
refer to the followings for more detail informations about the DIP settings:
DIP settings for lock.
DIP
OFF,OFF,OFF Applies to door station1 & lock 1
NOTE: See diagrams at the end of this manual, (6-7).
12V
S2
S1 GND
2-WIRE SYSTEM
RoHS
12V S2
S1 GND
Compliant
1
2
3
BUS BUS RISER
RISER
BUS BUS
Bit State
OFF,OFF,ON Applies to door station1 & lock 2
Descriptions
-4-