5.
MEASUREMENTS
FAN UNIT WITH HEAT RECOVERY
20
180
CONTROL UNIT
140
6.
INSTALLATION - WALL PREPARATION
Make a hole, through the whole thickness of the wall, of a minimum diameter of 162 mm, with an inclination of 1°
towards the exterior. The hole should be located at a minimum height of 2.3m from the ground and 100 mm from
the wall side (Figure 1).
Using two monostanza ventilation systems with Aspirvelo Air Ecocomfort heat recovery series in the same
environment, when mounted on the same wall (figure 2a), the installation must be carried out in such a way that
the centers of the drill holes are at a minimum distance of 1.2 meters.
max 530 - min 240*
max 280
max 280
POWER SUPPLY
150±10
min 100mm
E N G L I S H
A S P I R V E L O
AIR ECOCOMFORT
* For wall thickness of less than
47
280mm, cut the pipe according to
necessity and use a standard outdoor
grill (not supplied).
90
82.5
77
150±10
31
T case
ROOM
EXTERNAL
Figure 1
13