Angelo Po 090GRG Manual De Uso página 49

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

REPLACEMENT OF THE BURNER NOZZLE
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the control
panel (C).
4 - Unscrew the nozzle (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Replace the control panel (C) and the knobs (A)
on completion of the operation.
REPLACEMENT OF THE PILOT LIGHT INJECTOR
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Access the pilot light through the opening pro-
vided in the bottom of the appliance.
3 - Unscrew the union (A).
4 - Remove the nozzle (B) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Retighten the union (A).
DECOMMISSIONING THE APPLIANCE
Important
This operation must be carried out by
skilled operatives in compliance with the le-
gal requirements with regard to safety at
work. Never dump non-biodegradable ma-
terials, lubricating oils and non-metallic
A
B
C
A
B
components (rubber, PVC, resins, etc.) in
the environment. Dispose of them in ac-
cordance with the relevant legal require-
ments.
- 23 -
B
D
IDM-39616501700.tif
IDM-39604003800.tif
IT
GB
DE
FR
ES
English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

190grg

Tabla de contenido