STAND BY: When the shower is not in use, the screen remains o and no information is showing. The On/O button stays on with a
white light.
ON: When the On button is pressed, the screen and the buttons showing the functions available light up.
With no water owing out, 38°C is shown on the screen, which is the pre-selected default temperature, together with the last ow level
used. The temperature or ow level can be changed by pressing [+] or [-] without water ow. Any outlet can be chosen to start up the
system.
Upon selecting a temperature while a water outlet is active, the actual temperature is shown blinking on the screen until the pre-selected
temperature is reached. Opening or closing outlets does not alter the pre-selected temperature.
When the temperature of the cold water entering is higher than the temperature selected, or that of the hot water lower, the system
equates the water outlet temperature to that of the inlet and shows it blinking on the screen.
The temperature level selected is shown numerically and as a colour scale:
TEMPERATURE REACHED: By default, the system incorporates a function which closes the water outlet when the set temperature has
been reached. Press the button for the desired outlet so that the water can continue to ow. This function can be activated or deactivated
by following the instructions on page 3.
SAFETY STOP: The system blocks the water outlet under the following circumstances:
- In the event of cold or hot water supply failure. It reopens automatically when the supply returns.
- In the event of a power cut.
- If the temperature accidentally rises to above 50°C, the system is blocked for safety against scalding.
Press the
button to restart. If it still does not work, call the TRES Technical Service.
- The system switches itself o automatically after 15 minutes of operation without interaction with the user.
OFF: When the O button is pressed, the system closes automatically if any outlet is open, and an automatic calibration is carried out for a
few seconds during which "
button.
This button lights up when there is electric current. A beep sounds with the rst touch and the panel
comes on, lighting up to show the functions available. A second touch turns the panel o .
Cada toque de este botón emite un pitido e incrementa un nivel de caudal de 5 disponibles. No permite
pulsación prolongada. Cuando está ajustado al máximo, emite dos pitidos.
A beep sounds each time this button is touched, decreasing the ow by one level out of the 5 available.
Does not allow touch and hold. Two beeps sound when adjusted to minimum.
A beep sounds each time this button is touched, increasing the temperature by one level. Allows touch
and hold. Two beeps sound when adjusted to maximum.
A beep sounds each time this button is touched, decreasing the temperature by one level. Allows touch
and hold. Two beeps sound when adjusted to minimum.
A beep sounds when this button is touched, and the ow of water out of the shower head is activated.
The button blinks to indicate that the outlet is active. Touching again puts the system on pause,
maintaining the preselected ow and temperature values.
A beep sounds when this button is touched, and the ow of water out of the hand shower is activated.
The button blinks to indicate that the outlet is active. Touching again puts the system on pause,
maintaining the preselected ow and temperature values.