E N G L I S H
longer displayed.
5.13 Enabling Record
The recording of a new maximum or
minimum is indicated by beep sounds.
We can use RECORD in all modes of
this Meter, but we can not change
Meter modes while in RECORD, for
example, from voltage to amperes.
In the AC amperes mode, the bar
graph displays the rms value of
current flow and also blinking
pointers at the recorded MAX and
MIN. But, in the frequency mode,
the bar graph displays the rms value
of current flow only. No blinking
pointers.
In SOFT, the softened values of rms
current flow, frequency or voltage
is recorded for MAX, MIN, and AVG.
The bar graph displays
instantaneous values of rms current
with blinking pointers for MAX and
MIN.
In CREST (that is, PEAK) mode, the
half-cycle peak amperes are recorded
for MAX. In CREST mode, MIN and
AVG are not available. The bar graph
displays a single blinking pointer for
MAX.
The CREST (that is, PEAK) function is
not available in the other (V or Hz or
Ω) modes.
32
To stop recording, use the HOLD
pushbutton.
Then,
longer blinks, and the values of MAX,
MIN, and AVG are frozen. Press the
HOLD pushbutton again to restart
recording, when the values of MAX,
MIN, and AVG are not reset.
The recording simply starts again
from where it left off.
Press and hold the MIN-MAX
pushbutton for 2 seconds and then
release in order to exit RECORD. This
Meter acknowledges with a beep
sound and RECORD is no longer
displayed.
5.14 RECORD mode
After enabling RECORD, press the
MIN-MAX
pushbutton
through the MAX, MIN, and AVG
readings held in memory. If this Meter
is in CREST (that is, PEAK) function,
only MAX is held in memory.
Battery life limits the duration of
RECORD. The MAX reading is the
maximum
value
RECORD started.
The MIN reading is the minimum
value detected since RECORD started.
The AVG reading is calculated
continuously from the start of
RECORD.
To stop recording and to freeze the
values of MAX, MIN, and AVG in
memory, press the HOLD pushbutton.
RECORD
no
to
cycle
detected
since