Safety Instructions - Televes DIGINOVA BOSS Manual De Instrucciones

Ocultar thumbs Ver también para DIGINOVA BOSS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DIGINOVA BOSS Antenna
Specially designed for the reception of the
DTV (and ready to reject LTE/4G). The Diginova
antenna receives all available digital and HD
local programming in your area.
UV resistant protective ABS plastic radome
housing ideal to withstand adverse climate
conditions.
Compact, durable and unobstrusive design
provides low visual impact. Specially suited for
balconies and single-family homes.
Easy installation with its built-in heavy duty
mounting clamp.
BOSS-Tech
technology
provides
electrical performance and optimized output
leveles.
Manufactured using only the highest quality
materials providing the best resistance to
moisture, water, wind, extreme heat, etc.

Safety Instructions:

LIGHTNING PROTECTION
If installed outdoors, be sure the antenna system
is grounded so as to provide protection against
voltage surges and built-up static charges.
Section 810 of the National Electrical Code
ANSI/NFPA70, or CSA C22.1 sections 10, 16, and
54, of the Canadian Electrical Code, provide
information with respect to proper grounding
of the mast and supporting structure, grounding
of the antenna lead-in wire to an antenna
discharge unit, size of grounding conductors,
highest
location of antenna-discharge unit, connection
to grounding electrodes, and requirements
for the grounding electrode (see figure and
instructions).
Mount the lightning arrestor or 75 ohm coaxial
grounding block as close as possible to where
the 75 ohm coaxial cable downlead enters the
house.
The ground wires for both the mast and the
downlead should be copper or aluminum wire,
number eight (8) or larger.
The downlead wire from the antenna to the
lightning arrestor and the mast ground wire
should be secured to the house, spaced from four
(4) to six (6) feet apart.
In the case of a "ground up" antenna installation
it may not be necessary to ground the mast if
the mast extends four or more feet in the earth.
Consult a TV serviceman for the proper depth in
your location.
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
Antenna Lead
in Wire
Ground
clamp
Antenna Discharge Unit
Electric Service
(NEC Section 810-20)
Equipment
(May substitute a 75 ohm
Coax Grounding Block)
Grounding Conductors
(NEC Section 810-21)
Ground clamps
Power service Grounding Electrode System
(NEC Art 250, Part H)
NEC - National Electrical Code
WARNINGS
To prevent fire or shock hazard, do not expose
the included power supply to rain or moisture.
Installation of off-air antennas near power
lines is dangerous. For your safety, follow the
installation instructions.
Any alteration or modification to the product
or usage not in accordance with product
instructions voids the warranty.
6