SETTING LEVELS TO CONTROL
The MIE210MLP is capable to monitor two diff erent levels (Level 1 and Level 2). Those both
levels can be monitored separetly or simultaneously. To choose the confi guration wanted, just
follow the steps below:
1 - Disconnect the controller from the power supply.
2 - Hold the button
3 - Connect the controller to power supply while the button is pressed.
4 - Choose the desired option using the button.
5 - Disconnect the controller from the power supply and reconnect again without pressing
the button.
Short pulsation
MODIFY SENSOR TYPE
The equipment needs one or two sensors in order to control the minimum level (selector "CAR"
for Level 1 and selector "RPM" for Level 2). Those sensors could be NPN or PNP type.
For PNP type sensor
Put the "CAR" and/or "RPM" jumper to the P position
5
pressed
Short pulsation
Put the "CAR" and/or "RPM" jumper to the N position
For NPN type sensor