Maintenance
check the safety helmet regularly in accordance with the operating instructions.
check the face seal and the air nozzle for holes, cracks or other damage and check
that they are correctly positioned on the helmet (see operating instructions). Do not
use the system until all worn or damaged parts have been replaced.
Activity
cleaning, disinfection
Visual inspection
checking the air flow
charging the battery
If the unit is in storage the battery must be recharged every 4 months.
Cleaning
using a clean cloth moistened with soapy water, clean the blower, the air hose and
the safety helmet. Leave the unit to dry at room temperature. Do not use strong
detergents, solvents, alcohol or cleaning agents containing abrasives. the face
seal is washable (hand wash, do not spin).
Technical specifications
(we reserve the right to make technical changes)
nominal protection factor
tH2P classification (Europe)
tH2P classification (australia)
Blower unit
Flow rate: at least 150 l/min, controlled.
Material
Polyamide (PA-GF)
Blower
high-quality ball beared fan motor
Fuse
Electronic fuse
Battery
Li-Ion technology, running time:
standard battery (4.8 ah): min. 8 h
Long life battery (7.2 ah): min. 12 h
noise level
Max. 70 db(a)
warning signals
audible and visual warning when the battery is low, the air flow is
weak or a filter is missing
Filter
typ P sLR
Air hose
Length: 1160 mm, weight: 185 g
weight
1205 g (blower including filter and belt)
Dimensions
LxWxH: 249x213x87 mm
standards
En 12941:1998 tH2P
as/nZs 1716: 2003 PaPr P2
notified body
cE 1024 & sAI Global Lic 2824
Troubleshooting
Blower does not supply air
→ keep on/off button pressed for sufficient time
→ Wait at least 5 seconds before re-actuating the on/off switch
→ check the battery is charged and correctly fitted
→ remove the protective cap from the filter
Blower does not stop
→ keep on/off button pressed for sufficient time
→ Wait a few seconds before re-actuating the on/off switch
Air flow warning illuminates (red indicator)
→ Fit the filter
→ replace filter if clogged
→ rectify any blockages, kinks or loops in the hose
→ Ensure safety helmet is correctly connected
Battery warning illuminates (yellow indicator)
→ recharge or replace the battery
Battery can no longer be recharged
→ check the mains voltage at the plug connection
→ Defective battery – replace and dispose of the used battery in accordance with
the national regulations for special waste.
→ Defective charging unit – replace
Maintenance plan
System in use
After each use
Before and after each use
Before each use
After each use
Battery running time is too short
→ Defective battery – replace and dispose of the used battery in accordance with
the national regulations for special waste.
→ Defective charging unit – replace
Scope of supply/spare parts (see cover)
1 P sLr filter
2 VIZOR 3000 welder's helmet (incl. item 9), without cartridge
3 AirFilter 3000 PAPR (including items 1, 4a, 5-8)
4a standard battery (Li-Ion 4800 mAh)
4b Long life battery (Li-Ion 7200 mah)
5 Fabric belt with back support
6 Flow meter
7 air hose
8 Protective sleeve for air hose
9 Face seal
Further accessories can be obtained from the main catalogue or our website.
Legend (see cover)
1 Read the operating instructions prior to use
2 Do not use sharp objects to open
3 contents fragile
4 store with this side up
5 Protect from dampness
6 notified body's mark
7 contains lithium-ions
8 Plastic, recyclable
9 recommended storage temperature: +5 °c to +25 °c
10 Must not be disposed of with normal household waste. Please dispose of in
accordance with the national regulations for special waste.