Telcoma FM 400 Serie Manual De Instrucciones página 35

Receptor con autoaprendimiento
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
GB
The P2 output is now single-step. The output has no magnetic
hold, so if there is a power failure while the relay is activated,
the latter deactivates.
2. Timer output
- Press the key P2 3 times during programming.
- The led related to the pressed button gives 5
series of three blinks.
- Transmit with a remote control FM 400's series
during this stage.
- A fixed led light for a few moments indicates that
memorisation has been successful. The P2 output has now become
a timer. The timer is fixed for a time of approx. 30 seconds and cannot
be adjusted.
3. Code erasure
One or more codes may be erased from the memory of the receiver
with this operation.
- Press the key P1 or P2 4 times during programming.
- The led related to the pressed button gives 5
series of 4 blinks.
- During this stage, transmit with the radio
control FM 400's series to be erased. A fixed led
light for a few moments indicates that erasure
has been successful.
4. Erasure of all codes (reset)
The receiver storage is totally erased by
carrying out the reset.
- Press key P1 for at least 10 seconds until the
button LEDs light up simultaneously.
After a few seconds all the LEDs go out,
indicating that erasure is complete.
- Repeat the memorisation procedure.
3
(P3 - L3)
(P4 - L4)
4
P
L
P1
10 sec.
35