Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 2

Enlaces rápidos

Air Supply Requirements
1. Supply tool with 90 psig (6.2 bar) of clean, dry air. Higher pressure drastically
reduces tool life.
2. Connect tool to air line using pipe, hose and tting sizes shown in the diagram
on page 12.
3. Do not install a quick coupler directly into the tool throttle handle.
Lubrication
Use an air line lubricator with SAE #10 oil, adjusted to two drops per minute. If
an air line lubricator cannot be used, add air motor oil to the inlet once a day.
Noise & Vibration Declaration*
Sound pressure level 85 dB(A) in accordance with Pneurop 8N-1. For sound
power, add 10 dB(A).
Vibration value 3.3 m/s
2
re. ISO 8662-1
Maintenance
1. Disassemble and inspect air motor every three months if the tool is used every
day. Replace damaged or worn parts.
2. High wear parts are underlined in the parts list.
*These declared values were obtained by laboratory type testing in compliance with the stated
standards and are not adequate for use in risk assessments. Values measured in individual work
places may be higher than the declared values. The actual exposure values and risk of harm
experienced by an individual user are unique and depend upon the way the user works, the
workpiece and the workstation design, as well as upon the exposure time and the physical condition
of the user. We, Chicago Pneumatic, cannot be held liable for the consequences of using the
declared values, instead of values re ecting the actual exposure, in an individual risk assessment in
a work place situation over which we have no control.
To reduce risk of injury, everyone using, installing,
repairing, maintaining, changing accessories on, or
working near this tool must read and understand
these instructions before performing any such task.
The goal of Chicago Pneumatic is to produce tools that help you work safely and
e ciently. The most important safety device for this or any tool is YOU. Your
care and good judgment are the best protection against injury. All possible
hazards cannot be covered here, but we have tried to highlight some of the
important ones.
For Additional Safety Information Consult:
Your employer, union and/or trade association.
US Department of Labor (OSHA); www.osha.gov; Council of the
European Communities europe.osha.eu.int
"Safety Code for Portable Air Tools" (ANSI B186.1) available from:
www.ansi.org
"Safety Requirements for Hand-Held Non-Electric Power Tools"
available from: European Committee for Standardization,
www.cenorm.be
Air Supply and Connection Hazards
Air under pressure can cause severe injury.
Always shut o air supply, drain hose of air pressure and disconnect
tool from air supply when not in use, before changing accessories or
when making repairs.
Never direct air at yourself or anyone else.
Whipping hoses can cause serious injury. Always check for damaged or
loose hoses and ttings.
Do not use quick disconnect couplings at tool. See instructions for
correct set-up.
Whenever universal twist couplings are used, lock pins must be
installed.
Do not exceed maximum air pressure of 90 psi/6.2 bar or as stated on
tool nameplate.
Projectile Hazards
Always wear impact-resistant eye and face protection when involved
with or near the operation, repair or maintenance of the tool or changing
accessories on the tool.
Be sure all others in the area are wearing impact-resistant eye and face
protection.
Even small projectiles can injure eyes and cause blindness.
Operating Hazards
Always shut o air supply, relieve hose of air pressure and disconnect
tool from air supply when changing accessories.
Cutting with these tools will create sharp edges. Wear gloves to protect
hands.
We, Chicago Pneumatic Tool Company, 1800 Overview Road, Rock Hill, SC 29730 USA,
declare under our sole responsibility that the product to which this declaration relates, is in
conformity with the requirements of the Council Directive of June 1989 on the approximation
of the laws of the Member States relating to machinery (89/392/EEC).
Machine Name CP861 2-7/8" Cut-O Tool
Machine Type Power tool equipped for use with 3 in. diameter cutting wheels for metal
cutting - No other use is permitted
Serial No. Tools with No. 94200K, 01140L or higher
Technical Data
2.8 in. (73 mm) wheel capacity
Free speed 20,500 RPM
Air pressure 90 psi (6.2 bar)
Air consumption 17 cfm
Harmonized Standards Applied
EN292
National Standards Applied
ISO 8662-1, Pneurop 8N-1
Name and Position of Issuer
W. A. LeNeveu, President, Chicago Pneumatic Tool
Company
Signature of Issuer
Place and Date of Issue
Utica, NY 13501 USA, July 31, 1994
Limited Warranty: The "Products" of the Chicago Pneumatic
free from defects in material and workmanship
applies only to Products purchased new from
does not apply to products which have
been abused, misused, modi ed, or repaired by
than CP or its Authorized Service
Representatives. If
workmanship within one year after purchase,
return it to any CP Factory
Service Center for CP tools, transportation
prepaid, enclosing your name and address, adequate
of date of purchase, and a short
description of the defect. CP will, at its option, repair or
Products free of charge.
Repairs or replacements are warranted as described
of the original warranty period.
CP's sole liability and your exclusive
limited to repair or replacement of the defective Product. (There Are No Other Warranties Expressed
Or Implied And CP Shall Not Be Liable For Incidental, Consequential,
Any Other Damages, Costs Or Expenses
Excepting Only The Cost Or Expense Of Repair Or
Replacement As Described Above.)
Avoid direct contact with accessory and work surface during and after
work.
Cutting edges and saw blades can become hot during use. Do not
touch.
Never force the tool to cut faster or through heavier gauge material than
rated capacity.
To prevent damage to the tool and accessory, accessory must be held
rmly against work surface while cutting.
Workplace Hazards
Slip/Trip/Fall is a major cause of serious injury or death. Be aware of
excess hose left on the walking or work surface.
High sound levels can cause permanent hearing loss. Use hearing
protection as recommended by your employer or OSHA regulation (see
29 CFR part 1910).
Maintain a balanced body position and secure footing.
Repetitive work motions, awkward positions and exposure to vibration
can be harmful to hands and arms. If numbness, tingling, pain or
whitening of the skin occurs, stop using tool and consult a physician.
Avoid inhaling dust or handling debris from the work process which can
be harmful to your health. Use dust extraction and wear respiratory
protective equipment when working with materials which produce
airborne particles.
Proceed with care in unfamiliar surroundings. Be aware of potential
hazards created by your work activity.
Some dust created by power sanding, sawing, grinding, drilling and
other construction activities contains chemicals known to the State of
California to cause cancer and birth defects or other reproductive harm.
Some examples of these chemicals are:
- Lead from lead based paints
- Crystalline silica bricks and cement and other masonry products
- And Arsenic and chromium from chemically-treated rubber
Your risk from these exposures varies, depending on how often you do
this type of work. To reduce your exposure to these chemicals: work in a
well ventilated area, and work with approved safety equipment, such as
dust masks that are specially designed to lter out microscopic particles.
Additional Safety Topics
This tool and its accessories must not be modi ed.
This tool is not intended for use in an explosive atmosphere and is not
insulated for contact with electric power sources.
Operators and maintenance personnel must be capable of handling the
power of the tool and performing the job task.
For professional use only
CP861
Cut-O Tool
Model "K" & "L"
KF136502 Rev. G
Tool Company ("CP") are warranted to
for one year from the date of
purchase. This Warranty
CP or its authorized dealers.
Of course, this Warranty
someone other
a CP Product proves defective in
material or
Service Center or Authorized
replace defective
above for the remainder
remedy under this Warranty is
Or Special Damages, Or
be
proof

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Chicago Pneumatic CP861

  • Página 1 Products free of charge. Repairs or replacements are warranted as described above for the remainder of the user. We, Chicago Pneumatic, cannot be held liable for the consequences of using the of the original warranty period. CP's sole liability and your exclusive...
  • Página 2: Instrucciones De Seguridad

    El objetivo de Chicago Pneumatic es fabricar herramientas que le ayuden en su Los filos de corte y las hojas de serrar pueden calentarse durante la operación.
  • Página 3: Consignes De Securite

    Chicago Pneumatic ou ses unités de service agréés. Si un produit Chicago Pneumatic présente un vice de matériel ou *Ces valeurs ont été obtenues par des essais en laboratoire conformément aux normes indiquées;...
  • Página 4: Norme Di Sicurezza

    CP861 Utensile tagliare CP861 La Chicago Pneumatic Tool Company, 1800 Overview Road, Rock Hill, SC 29730 USA, Alimentazione dichiara sotto la propria responsabilità che il prodotto al quale si riferisce la presente 1. Alimentare l'utensile con aria pulita e secca a 6,2 bar. Una pressione più elevata dichiarazione è...
  • Página 5 återstoden av den ursprungliga garantiperioden. CP:s enda ansvar och fysiska tillstånd. Vi, Chicago Pneumatic, kan ej hållas ansvariga för följder vid användning av er enda gottgörelse enligt denna garanti är begränsad till reparationeller utbyte av den defekta produkten.
  • Página 6: Sicherheitshinweise

    CP861 CP861 Stechdrehmeißel Wir, die Chicago Pneumatic Tool Company, 1800 Overview Road, Rock Hill, SC 29730 USA, Anforderungen an die Luftversorgung erklären unsere alleinige Verantwortung dafür, daß das Erzeugnis, auf das sich diese Erklärung 1. Versorgen Sie das Werkzeug mit 90 psig (6,2 bar) sauberer, trockener Luft. Ein bezieht, mit der Richtlinie des Europäischen Rates 89/392/EWG vom Juni 1989 über die...
  • Página 7: Instruções De Segurança

    Garantia Limitada: Os Produtos Automotive Service Tool (seguidamente designados "Produtos") da regulador de três em três meses, se a ferramenta for utilizada diariamente. Chicago Pneumatic Tool Company ("CP") estão garant idos contra defeitos de material e fabrico por um Substituir as peças gastas ou danificadas.
  • Página 8 Norsk (Norwegian) CP861 Avskjæringsverktøy Vi, Chicago Pneumatic Tool Company, 1800 Overview Road, Rock Hill, SC 29730 USA, Krav til lufttilførsel erklærar under eneansvar, at produktet som beskrives nedenfor er i samsvar med 1. Fyll verktøyet med 6,2 bar (90 psig) ren, tørr luft. Høyere trykk reduserer kravene i Kommisjonens direktiv av juni 1989, vedrørende harmonisering av...
  • Página 9: Aanvullende Veiligheidsvoorschriften

    CP861 CP861 Afkortmachine Ondergetekende, Chicago Pneumatic Tool Company, 1800 Overview Drive, Rock Hill, SC Luchttoevoervereisten 29730 USA, verklaart hierbij dat het produkt waarop deze verklaring betrekking heeft, in 1. Sluit het gereedschap aan op schone, droge lucht met een druk van 6,2 bar (90 overeenstemming is met de in juni 1989 door de Raad van de Europese Gemeenschap psig).
  • Página 10: Sikkerhedsinstrukser

    Chicago Pneumatic, kan ikke påtage os noget ansvar for anvendelse af de ovenstående værdier i (Denne ovenstående garanti træder i stedet for alle andre garantier eller betingelser, udtrykte og stedet for anvendelse af værdier, der er opnået i den faktiske arbejdssituation, som grundlag for...
  • Página 11 CP861 CP861 laikkaleikkuri Chicago Pneumatic Tool Company, 1800 Overview Road, Rock Hill, SC 29730 USA, Ilmansaantivaatimukset vakuuttaa ainoana vastuunhaltijana, että tämän todistuksen kattama tuote täyttää kaikki 1. Työkalu tarvitsee 6,2 bar (90 psi) puhdasta, kuivaa ilmaa. Tätä korkeampi Euroopan yhteisön kesäkuussa 1989 annetun jäsenmaiden koneturvallisuutta koskevia paine vähentää...
  • Página 12 Air Supply Diagram 1/2" (12mm) CA048362 (1/2") 1/2" (12mm) CA048360 (1/2") CA048361 (1/2") 1/4"NPT 3/8" (10mm) FOR DETAILED INFORMATION ABOUT CHICAGO PNEUMATIC AIR TOOLS AND EQUIPMENT CONTACT: HEADQUARTERS LOCATION BRASIL INDIA SOUTH AFRICA SWEDEN UNITED STATES Chicago Pneumatic Brasil Consolidated Pneumatic Tool...

Tabla de contenido