Unitek ALPHA 500 inT Manual Del Usuario página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. ERROR MESSAGE OF THE TEST
6.1 During the test, if the UPS emits a quick beep, it means the battery level is low. Please leave the UPS in normal
mode for at least 10 hours, and the batteries will be fully charged.
6.2 If the UPS emits a continuous beep during the test, it may be in an overload situation. The over load may result in
an unexpectedly short runtime during a blackout. Please turn off the computer and check if any equipment can be
removed from the UPS.
6.3 If the UPS emits a continuous urgent beep for 12 seconds after test, it means that the batteries are no good and
may need replacement.
6.4 The frequency auto-select function allows the UPS to detect the city power frequency and apply the appropriate
one (50 ~ 60Hz).However, if the frequency of city power is abnormal (outside the range 47 - 68Hz) the UPS will switch
to backup mode for protecting your computer (even the city power voltage is O.K.).
6.5 LED/Alarm Indication:
Visual, audible indicator
Green LED, no alarm
Red LED flashing, slow beeping, 2 beeps / 4 sec.
Red LED flashing, quick beeping, 4 beeps / sec
Red LED flashing, urgent beeping, 8 beeps / sec
Red LED flashing, long beep
Red LED flashing, one beep / 4 sec.
If any abnormal condition occurs, and the item 5.3 can not be executed, you will need to reset your UPS. Please push
the button for at least 10 sec. to shut down the UPS, and push the button again to re-start the UPS.
7. COMPUTER INTERFACE PORT
Pin2 : AC Power Failure
Pin4 : Common GND of Pin2 & Pin5
Pin5 : UPS Battery Low
Pin6 : Turn off UPS
Pin7 : GND of Pin6
The computer interface port is diagramed above for
your reference. Use Pin4 as the common of Pin2
and Pin5, Pin2 and Pin4 will become close loop from
open when the utility is fail, Pin5 and Pin4 will
become close loop from open when the battery level
is low.
The UPS will shut down when the high level from RS-232, sustained for 3 seconds, is applied between Pin6 and Pin7.
Operating status
City power normal.
Backup mode.
Low battery
Battery Replacement needed
Over load
( < 180 W -- Alarm & auto shut down in 30 sec.)
( < 230 W -- Auto shut down immediately)
No load (auto shut down after 30 sec.)
Computer
5 4 3 2 1
RS232
9 8 7 6
13
8.BUTTON FUNCTION ON FRONT PANEL
Pushing when in normal mode: Self test
Pushing when in backup mode: Alarm reset (silence)
Pushing for 4 sec. in any mode: Power off manually
9. SPECIFICATION:
MODEL
Capacity (Computer Load)
Max. Load recommended
Voltage
Input
Frequency
Voltage
Output
Frequency
Wave Form
Runtime of one set of P.C.
Transfer Time
Battery : Type
Battery : Voltage / Capacity
Battery : Recharge Time
LED/Alarm Indication
Normal / In charge
Back up / Abnormal Input Voltage
Power Saving (When No Load)
Low Battery
Battery Replacement
Over Load/Fault
Abnormal Input Frequency (Back up)
Operation Temp.
Operation Humidity
Dimensions (L*H*W)
Weight (N.W./G.W. KG)
ALPHA 500 inT
300VA
< 180W
100V/110V/115V/220V/230V/240V ± 15%
50Hz/60Hz Auto detect
100V/110V/115V/220V/230V/240V, ±5% for Back-up Mode
50Hz or 60Hz ± 0.1Hz
Simulated Pseudo Sine Wave
8 min. Typical
4ms Typical.
Maintenance Free, Lead-Acid
6V 3.3Ah x 2pcs
Approx. 8 hrs to 90%
GRN LED, No Beep.
RED LED Flashing, 2 Beeps / 4 sec.
RED LED Flashing,1 Beep / 4 sec. (Auto off in 30 sec.)
RED LED Flashing, 4 Beeps / sec.
RED LED Flashing, 8 Beeps/ sec.
RED LED Flashing, Continuous Beep.
RED LED Flashing, No Beep.
0-40
30-95% Non-Condensing
242 x 144 x 40 (mm)
3 / 3.5 (kgs)
14

Publicidad

Tabla de contenido
loading

Tabla de contenido