Under normal charge circumstances, the LEDs operate as follows:
To reset charger after 100% charge (Green LED), disconnect the DC plug
from battery for more than 30 seconds. Then, reconnect DC plug.
JC1
Ammeter
(Amber)
80% Charge
(Amber)
100% Charge
(Green)
AC On
(Amber)
Fault
(Red)
MAINTENANCE
On:
Displays
approximate scale
of current output
during Step 2.
Blinking:
High internal
charger
temperature.
Current output
reduced.
On:
80% charged, Step
2 complete. Begin
Step 3.
Blinking:
With no battery
connected,
indicates algorithm
# selected by
number of flashes
at startup.
On:
Charging
complete.
Charger in
Storage Mode.
Blinking:
Step 3 complete.
Begin Step 4.
On:
AC power good.
Blinking:
Charger may be
overheated.
Move charger to
cooler location.
Blinking:
Charger error.
Refer to
Troubleshooting
on next page.
1
2
3
4
5
6
7
8
9
10
11
Y-1679
7-14