Inside the pump, lubricants are used which
may
contaminate
discharged in case of any improper
operation or damage of the device. The
lubricants used are biologically degradable and non-
hazardous to health.

3. TECHNICAL DATA

Model
Mains voltage / frequency
(V / Hz)
Nominal performance (Watts)
Protection type (IP)
Pressure port
Max. flow rate (Qmax)
(l/h)
(1)
Max. pressure (bar)
Max. delivery height
(Hmax)
(m)
(1)
Max. submersion depth (m)
Max. size of the solids being
pumped (mm)
Max. fluid temperature
(Tmax) (°C)
Min. fluid temperature (°C)
Length of connection
cable(m)
Cable type
Weight (net) (kg)
Dimensions (L x D x H) (mm)
1) The values were determined with free, unreduced outlet.

4. SCOPE OF DELIVERY

The scope of the delivery of this product includes :
One pump with connection cable, two connection
ports, one operating manual.
Please verify that the scope of delivery is complete.
Depending on the purpose of the application, addi-
tional accessories may be necessary (please refer to
the chapters titled "Installation" and "How to order
spare parts").
If possible, keep the packing until the warranty peri-
od has expired. Please dispose of the packing mate-
rials in an environmental-friendly manner.

5. INSTALLATION

the
liquids
being
5.1. GENERAL INSTALLATION INFORMATION
VCD-1000-I
All connection lines have to be perfectly tight since
220-240/50
leaking lines may affect the performance of the
pump and cause considerable damage. If required,
1000
please use a suitable sealant to make the installation
airtight.
X8
F40/49 (1"1/2)
When tightening threaded connections, please do
not apply excessive force which may cause damage.
19 500
When laying the connection pipes, you should
0,9
make sure that the pump is not exposed to any
9
form of weight, vibration or tension. Moreover, the
connection lines must not contain any kinks or an
7
adverse slope.
Please observe the illustrations.
35
5.2. INSTALLATION OF THE PRESSURE LINE
35
The pressure line conveys the liquids to be discharged
from the pump to the point of withdrawal. To avoid
5
dynamic flow losses, one should use a pressure line
having at least the same diameter as the pressure
1,5
port (1) of the pump.
H07RN-F
1. Screw the connection elbow (9) into the pump
7,6
183x160x392
2. Screw the combination nipple (10) into the
3. Fix a hose to the combination nipple.
The combination nipple can be trimmed to suit the
selected hose connection. Use the largest possible
hose diameter.
5.3. STATIONARY INSTALLATION
If the unit is used in a stationary installation, rigid pipes
have proven to be the ideal choice for the pressure
lines. In this type of installation, we recommend that
you incorporate a check valve (non-return valve) in
the pressure line immediately following the pump
outlet so that no liquid will flow back after the pump
cuts out. To facilitate maintenance work, we also
recommend the installation of a stop cock valve
downstream of the pump and check valve. This
arrangement is beneficial in that closing the stop
cock will prevent the pressure line from running dry
after the disassembly of the pump.
During the entire process of installation, the
device must not be connected to the
electrical mains.
The pump and the entire connection
system have to be protected from frost.
outlet.
connection elbow.